Band pass filter options, Thrust position measurement options – Rockwell Automation 1440-SDM02-01RA XM-124 Standard Dynamic Measurement Module Manuel d'utilisation
Page 75

Rockwell Automation Publication 1440-UM001C-EN-P - May 2014
75
Configure the XM-124 Standard Dynamic Measurement Module
Chapter 2
Band Pass Filter Options
The Band Pass Filter options apply to the Band Pass Filter measurement mode
and affect the Band Pass Filter measurement.
Thrust Position Measurement Options
The Thrust Position measurement options apply to the Thrust Position
measurement mode and affect the Thrust Position measurement.
In this field
Values are
Comments
Min Frequency
25 to 1000 Hz
The high pass corner frequency or low cutoff frequency of the
band pass filter.
Max Frequency
100 to 5500 Hz
The low pass corner frequency or high cutoff frequency of the
band pass filter.
Parameter Name
Values are
Comments
Output data unit
Select mil or μm.
The units of the Thrust Position measurement
value.
Target Angle
Sets the angle between the shaft and the target surface. The target
surface moves with the shaft. The transducer is mounted
perpendicular to the target surface.
degrees
Upscale
Sets the movement of the target relative to the transducer that is
considered positive displacement.
Options:
• Away
• Towards
Calibration Offset (XM Serial Configuration Utility
only)
Enter the position of the current Transducer DC Bias reading.
mils