Class attributes, Instances, Class attributes instances – Rockwell Automation 1440-SDM02-01RA XM-124 Standard Dynamic Measurement Module Manuel d'utilisation
Page 128

128
Rockwell Automation Publication 1440-UM001C-EN-P - May 2014
Appendix B
CIP Objects
Class Attributes
Instances
There are 51 instances of this object
Table 47 - Parameter Object Class Attributes
Attr ID
Access Rule
Name Data
Type
Description
Semantics
2
Get
Max Instance
UINT
Maximum instance number of an
object in this class.
Total number of parameter object
instances.
8
Get
Parameter Class
Descriptor
WORD
Bits that describe the parameter.
Bit 0 Supports Parameter Instances
Bit 1 Supports Full Attrib.
Bit 2 Must do nonvolatile store
Bit 3 Params in nonvolatile
9
Get
Config. Assembly
Instance
UINT
Set to 0
Table 48 - Parameter Object Instances
Instance
Read
Only
Name
Data Type
Valid Values
Default Value
1
No
Transducer 1 Sensitivity Units
USINT
0 = mil
1 = in/s
2 = g
3 = psi
4 = volts
5 = mm/s
6 = μm
7 = Pa
8 = mbar
0
2
No
Transducer 2 Sensitivity Units
USINT
(same as above)
0
3
No
Channel 1 Measurement Units
USINT
0 = mil
1 = in/s
2 = g
3 = psi
4 = volts
5 = mm/s
6 = μm
7 = Pa
8 = mbar
0
4
No
Channel 2 Measurement Units
USINT
(same as above)
0
5
No
Starting Order for Channel 1Sum
Harmonics meas.
USINT
0=1
1=2
2=3
3=4
4=5
3
6
No
Starting Order for Channel 2 Sum
Harmonics measurement.
USINT
1…5
2