2 external bus connections – Metrohm 730 Sample Changer Manuel d'utilisation
Page 26
Advertising

2.5 Integration
730 Sample Changer, Installation
23
2.5.2 External Bus Connections
Four dosing instruments may be connected to the "External Bus"
interface using a 729 Dosimat Interface. Up to three Dosimat In-
terfaces may be connected in line (daisy chaining) and be assem-
bled with dosing instruments. Each interface must be addressed
correctly.
Thus it is possible to operate 12 dosing units using the DOS com-
mand of the 730 Sample Changer.
730
700
685
729
Dos. 2
Dos. 1
729
EBus
Adress 2
729
Dos. 3
Dos. 4
EBus
Adress 3
EBus
Adress
1
700
685
700
685
Dos. 5 ... 8
Dos. 9 ... 12
EBus
Adress 0
Addresses:
"External Bus"-
Address
Dosing Unit
Sample Changer
0
1. Interface
1
Dos. 1 … Dos. 4
2. Interface
2
Dos. 5 … Dos. 8
3. Interface
3
Dos. 9 … Dos. 12
Cable 6.2135.000
Cable 6.2134.000
Advertising