INSTALLATION

GAS HOOK-UP

LP TANK RESTRAINT FOR BUILT-IN INSTALLATION

If the grill is to be installed in a Built-in application, then the grill must be installed in accordance with the

Built–in installation guidelines.

If you intend to operate your Built-in grill on LP gas utilizing a 20 lb Type 1 cylinder, then the Built-in LP tank

restraint must be installed prior to initial use of the grill. If you do not have one please contact DCS Customer Care

at (888) 936-7872 for information on obtaining one.

The following steps will illustrate how to properly locate and install the LP tank restraint within the Built-in enclo-

sure.

NOTE:

The grill comes with the LP Regulator/Hose assembly installed at the factory. The assembly, along with the entire grill

system, is leak tested.
Do not remove the Regulator/Hose assembly from the grill during installation.

Fig. 24

18” max.

The maximum distance from the center

of the manifold cut out to the center of

the tank restraint is 18 inches.

Center of manifold cut

out projected to floor

of the island.

Tank Restraint can be placed

within this area without causing

stress on the LP regulator hose

connection.