Installation instructions, Inst alla tion instructions, Cooktop installation (cont.) – GE Profile 30 Inch Built-In Gas Cooktop Owners Guide Manuel d'utilisation

Page 26: Install the pressure regulator

Advertising
background image

26

49-2001159 Rev. 0

17. INSTALL THE PRESSURE REGULATOR

WARNING

EXPLOSION HAZARD: do not

exceed 25 ft-lbs. of torque when making gas
line connections. Overtightening may crack the
pressure regulator resulting in fire or explosion
hazard.

• You must use the gas pressure regulator supplied

with this range.

• Shut off the main gas supply valve before

disconnecting the old cooktop and leave it off until

WKHQHZKRRNXSKDVEHHQFRPSOHWHG'RQWIRUJHW

to relight the pilot on other gas appliances when you
turn the gas back on.

• For all connections, use a pipe sealant approved by

ORFDOFRGHVDQGUHVLVWDQWWRWKHDFWLYLW\RI/3JDV

• Install the pressure regulator in the gas line as close

to the cooktop inlet as possible to allow clearance for
ventilation ducting.

• Make sure the arrow on the body of the regulator

is pointing straight up and toward the cooktop. Any
other position will affect the output pressure of the
regulator. This arrow indicates correct flow of gas.

• Install a manual gas line shut-off valve in an easily

accessible location.

NOTE:

Instead of using solid piping to connect

WRSUHVVXUHUHJXODWRUDQDSSURYHGIOH[LEOHPHWDO

appliance connector may be used between the
shut-off valve and the pressure regulator, if local
codes permit.

• If the hard piping method is used, you must carefully

align the pipe. The cooktop cannot be moved after
the connection is made.

• Appropriate flare nuts and adapters are required at

HDFKHQGRIWKHIOH[LEOHFRQQHFWRU

TEST FOR LEAKS

WARNING

'212786($)/$0(72&+(&.

)25*$6/($.6'RQRWXVHWKHFRRNWRSXQWLODOO

connections have been leak tested.

3HUIRUPOHDNWHVWSHUWKHIROORZLQJLQVWUXFWLRQV
3XUFKDVHDOLTXLGOHDNGHWHFWRURUSUHSDUHDVRDS

solution of one part water, one part liquid detergent.

2. When all connections have been made, make sure

all cooktop controls are turned to OFF and turn the
gas supply valve to ON.

3. Apply the liquid leak detector or the soap solution

around all connections from the shut-off valve to the
cooktop.

4. A leak is identified by a flow of bubbles from the

area of the leak.

5. If a leak is detected, turn the gas supply off. Tighten

the fitting. Turn the gas on and test again.

If the leak persists, turn the gas supply off and

FRQWDFW\RXUGHDOHUIRUDVVLVWDQFH'RQRWDWWHPSWWR

operate the cooktop if a leak is present.

IMPORTANT:

'LVFRQQHFWWKHFRRNWRSDQGWKH

individual shut-off valve from the gas supply piping
system during any pressure testing of that system

DWWHVWSUHVVXUHVJUHDWHUWKDQSVLJ,VRODWH

the cooktop from the gas supply piping system by
closing the individual manual shut-off valve to the
cooktop during any pressure testing of the gas
supply piping system at test pressures equal to or

OHVVWKDQSVLJ

Installation Instructions

COOKTOP INSTALLATION (Cont.)

INST

ALLA

TION INSTRUCTIONS

Advertising