Installation continued – Garland M/MST70 MASTER SERIES HEAVY DUTY GAS FRYERS Manuel d'utilisation
Page 9

Part # Rev 1.1382677 (11/12)
Page 9
INSTALLATION Continued
Assembly Instructions
M-Series Low Profile Backguard
1. Remove flue cap #6 by removing six (6) [#10] sheet metal
screws.
2. Remove front panel #5 by lifting upward.
3. With back panel #4 still attached to the left #2 and right
#3 uprights, drop uprights into the rectangular cutouts at
the rear of the range #1.
4. Fasten uprights #2 and #3 to the range #1 with four (4)
5/16” -18 bolts and flat washers #7 and #8.
5. If unit is in a battery lineup, fasten adjacent units together
at hole marked “X” with 1/4” -20 bolts, nuts, and washers.
6. Install front panel #5 previously remove.
7. Install flue cap #6 previously removed.
~
~
1
"X"
"X"
2
5
8
7
3
6
9
4
Assembly Instructions M-Series Backguard
1. Remove front panel #5 by lifting upward.
2. With back panel #4 still attached to the left #2 and right
#3 uprights, drop uprights into the rectangular cutouts at
the rear of the range.
3. Fasten uprights #2 and #3 to the range #1 with four (4)
5/16” -18 bolts and flat washers #6 and #7.
4. If unit is in a battery line up, fasten adjacent units
together at hole marked “X” with 1/4” -20 bolts and
washers.
5. Install front panel #5 previously removed. Attach front
panel #5 to range #1 with sheet metal screws.
1
"X"
"X"
2
5
8
4
3
6
7