Trouble shooting and adjustments continued – Garland M/MST70 MASTER SERIES HEAVY DUTY GAS FRYERS Manuel d'utilisation

Page 16

Advertising
background image

Part # Rev 1.1382677 (11/12)

Page 16

TROUBLE SHOOTING AND ADJUSTMENTS Continued

Thermostat Calibration

To calibrate the Fenwal Thermostat, fill the frypot to the FULL

mark with frying compound and turn the burner on. Insert a

thermometer in the center of the frypot with the bulb about

two inches below the surface. Allow the burner to cycle

about four times, the thermometer reading should be within

5° of the thermostat knob setting. If this does not agree with

the pointer of the thermostat knob:

1. Loosen the two set screws on the thermostat knob
2. Set the pointer at the temperature indicated on the

thermometer.

3. Tighten the set screws firmly.
4. Be sure the black surface of the knob is spaced away

from the dial plate at least the thickness of a dime.

NOTE: DO NOT TURN ADJUSTING SHAFT MORE THAN TWO

TURNS IN EITHER DIRECTION OR PERMANENT DAMAGE CAN

RESULT. THIS ACTION MAY VOID THE STANDARD WARRANTY.

The Fenwal Thermostat is an electric switch with contacts

that open on a temperature rise. It will respond to

temperature changes of approximately 1º when the fryer is

idling with no food being fried.

Turning the adjusting shaft counter-clockwise increases the

temperature at which time the contacts will open. Some of

the most common problems occur in connection with the

pilot generator. These usually show as poor ignition of the

main burner or frequent pilot outage.

Below is a diagram of how the Fenwal thermostat and Hi-

Limit controls are wired to the safety system.

BLK

BLK

WHT

WHT

HI-LIMIT

THERMOSTAT

OPERATING

THERMOSTAT

PILOT

GENERATOR

OPTIONAL ON OFF SWITCH

Advertising