August 6, 2003 / 6 Août, 2003
3
Manual / Manuel 0-2958
8. Connect the pilot wire (+) on the ATC Adapter or Torch Leads wire to the pilot connector on the Power
Supply.
9. Connect the plasma line provided in this kit to the Power Supply plasma connector. Do not use sealant.
Tighten securely.
10. Cut the plasma line to length as needed. Connect the plasma line to the plasma connector on the RPT Adapter
Kit negative / plasma fitting. Push in on the connector, insert the plasma line fully, and release the connector.
Check for a secure connection.
11. Ensure that there is no strain on any of the connections. Secure the Strain Relief Dome Nut to the Strain Relief
by hand. Do not overtighten.
12. Reinstall the Power Supply cover.