Tweco 7-3432 Manuel d'utilisation
General information, Parts supplied, Installation

October 7, 2002 / 7 Octobre 2002
1
Manual / Manuel 0-2764
Manual 0-2764
RPT Adapter Kit
Catalog No. 7-3432
Installation Instructions
General Information
This Replacement Torch Adapter Kit connects the Thermal Dynamics Plasma RPT Series Cutting Torch to the follow-
ing equipment:
DAIHEN SC-60P
MILLER Plazcut 60 / Zipcut
Parts Supplied
The kit includes:
• Control Connector Plug with Connectors
• Adapter Fittings ( 2 )
Installation
Install the Adapter Kit as follows:
1. Turn OFF the power supply.
2. Disconnect the main input power to the power
supply.
3. Remove the existing torch from the power sup-
ply, removing covers as required.
4. Place the appropriate Adapter Fitting into the
Power Supply torch power cable fitting ( - ) and
tighten securely. Do not use thread sealant.
Retain the unused fitting for possible future
use.
5. Connect the pilot wire (+) from the replacement
torch to the Power Supply and tighten securely.
6. Connect the Negative / Plasma Lead from the
replacement torch to the Adapter Fitting. Slide
the protective boot over the lead connection.
7. Connect the Control Connector Plug (see
NOTE), with two connectors, to the two mating connectors
on the replacement torch leads.
8. Connect the Control Connector Plug to the Power Supply.
NOTE
For Mechanized Systems refer to the
Torch Control Cable Wiring Diagram
on the last page of this Manual.
WARNING
Make sure that the Control Connector
Plug wires DO NOT contact the
Adapter Fitting after all leads are con-
nected.
Torch Control
Connectors
Pilot Lead
Torch Lead Assembly
Negative/Plasma Lead
A-01234
Adapter Fitting
Control Connector
Plug with Connectors
To
Po
wer Supply
(-) Fitting
To
Po
wer Supply
Control Connector
To
Po
wer Supply
Pilot Connector
© 2000 Thermal Dynamics Corp., Printed in USA /
Imprimé aux Etats-Unis d’Amérique
82 Benning Street, West Lebanon, NH 03784 USA
(603) 298-5711 • www.thermal-dynamics.com