General Information
This kit connects Thermal Dynamics Torches equipped with O2B connectors, or the ATC Adapter Kit, to the follow-
ing Power Supplies:
• L-TEC* PowerCut 875*, PowerCut 1125*, PowerCut 1500*
Supplied Parts
The kit includes:
• Adapter Assembly
• Hex Nut
• Flare Fitting
• Connection Cover
• Jumper Assemblies (2)
• Strain Relief
• Mounting Hardware
• Instructions
WARNINGS
Disconnect primary input power to the system before starting the installation.
Shut off the gas supply and bleed down the system.
Only a qualified technician should perform this procedure.
Procedure
A. Preparation
1. Disconnect and remove the original torch per the Power Supply operator's manual.
2. Remove the securing nut from the Strain Relief provided in this kit.
3. Install the Strain Relief on the torch connections cover included in this kit. Secure the Strain Relief with the
securing nut.
4. Pass the end of the Torch Leads or ATC Adapter Kit through the Strain Relief. Do not tighten the strain relief
dome nut.
5. Use mating fittings on the two wire assemblies provided in this kit to connect the assemblies to the mating
connectors on the Torch Leads or ATC Adapter Kit.