B. Installation
For All Installations:
1. Refer to the following illustration. Securely connect the two Control Wire Connectors provided in this kit to the
torch control terminals on the Power Supply torch connection panel.
2. For Hand Torch or ATC Adapter Installations only:
Re - connect the two torch leads or adapter kit mating connectors disconnected previously. Slide the insulating
sleeve removed previously onto these two leads. Ensure that the sleeve covers the mating connectors com-
pletely. Secure the sleeve in place with a tie wrap provided in this kit.
3. Thread the smaller end of the gas fitting from this adapter kit onto the power supply torch connector. Tighten
securely. Do not use sealant.
4. Connect the negative / plasma lead fitting (on the torch leads or ATC Adapter) to the gas fitting previously
installed on the Power Supply. Tighten securely. Do not use sealant.
Torch Leads
Assembly
ATC Adapter Kit
Through-Hole
Protector
Securing Nut
Through-Hole
Protector Dome Nut
Through-Hole
Protector Assembly
Torch Leads
or
ATC Adapter Kit Leads
Torch Adapter
Connection Cover
Torch Control
Terminals
Control Wire
Connectors (2)
Art # A-03942
Mounting Hardware
Or
Torch
Connector
Adapter
Fitting
Insulating
Sleeve
Pilot Lead
Hex Nut
Flare Fitting
Torch
Control
Wires
Torch Connection Opening
in Power Supply Front Panel
Ring
Terminal
Small
Adapter Fitting
Small
Connection
Fitting
Negative/Plasma
Lead Fitting
Tie Wrap
Bottom Flange
Connections for Hand Torch Leads with O2B Connector, or for ATC Adapter (for Hand or Machine Torch)