16. Slide the strain relief securing nut onto the ATC

Adapter Leads or torch leads assembly. Thread
the nut onto the strain relief securely. Do not
tighten the strain relief onto the torch leads.

17. Inside the power supply, loosely connect the nega-

tive/plasma lead fitting on the ATC Adapter or
torch leads assembly to the RPT Adapter. Hold
the Adapter assembly stationary with a tool grasp-
ing the narrow hex nut. Use another tool to turn
the ATC Adapter or torch leads negative / plasma
lead onto the adapter assembly. The adapter in-
cludes a pair of wires with an insulated 'faston'
connector on the ends. This wire assembly must
be in a horizontal position, leading from the
adapter assembly toward the outside of the power
supply, and parallel to the solenoid assembly.

CAUTION

This positioning is important for proper power sup-
ply and torch operation.

18. Slide one of the insulating sleeves included in this

kit onto the ATC Adapter kit or torch leads pilot
lead (with the butt splice). Crimp power supply
wire #25 into the butt splice. Check for a secure
connection. Slide the insulating sleeve along the
wire to cover the butt splice. Secure the sleeve in
place with one of the wire ties included in this
kit.

19. Slide the second insulating sleeve included in this

kit onto the RPT Adapter wires with the insulated
'faston' connector. Connect this connector to the
power supply 'faston' connector previously dis-
connected from the original torch assembly. Slide
the insulating sleeve along the wire to cover the
'faston' connector. Secure the sleeve in place with
one of the wire ties included in this kit.

20. This adapter kit includes a wire harness assem-

bly with a four - pin connector. Connect the mat-
ing connectors on this harness to the mating wire
connectors on the ATC Adapter Assembly or torch
leads assembly. Connect the four - pin connector
to the power supply circuit board inside the power
supply front panel.

21. Reinstall the power supply cover per the power

supply manufacturer's instructions.

22. In installations with the ATC Adapter, connect the

torch ATC male connector to the ATC Adapter
receptacle. The connectors should push together
with a very small amount of pressure. Secure the
connection by turning the locking nut clockwise
until it stops. DO NOT use the locking nut to pull
the connection together.

A-03627

1

2

ATC Male
Connector

ATC Adapter
Female Receptacle

Torch Leads

To

Power Supply

Torch Connection - Torch with ATC Male

Connector, Power Supply with ATC Adapter

23. Check the torch for proper consumables per the

torch manual.

24. Reconnect the power supply to primary input

power and the gas supply.

25. Test the system for proper operation.

NOTE

Every effort has been made to provide com-
plete and accurate information in this manual.
However, the publisher does not assume and
hereby disclaims any liability to any party for
any loss or damage caused by errors or omis-
sions in this Manual, whether such errors re-
sult from negligence, accident, or any other
cause.

Advertising