4. Connect the Control Connector Wires (see NOTE), with two connectors, to the two mating connectors on the
replacement torch leads.
Torch Control
Connectors
Pilot Lead
Torch Lead
Assembly
Negative/Plasma Lead
Art # A-03840
Control Connector
Wires with Connectors
To
Po
wer Supply
(-) Fitting
To
Po
wer Supply
Te
rm
inal C
onnections
To
Po
wer Supply
Pilot C
onnector
Spade Lugs
Not Present in
All Applications
NOTE
For Mechanized Systems refer to the Torch Control Cable Wiring Diagram on the last page of this Manual.
5. All Applications: Connect the spade lugs of the Control Connector Harness Wires to the Power Supply as
follows:
Wire No.
Terminal No.
1
2
3
3
4
4
1 (Jumper Wire)
6. When connecting a Model SL60 or SL100 torch to a Spectrum 500 or Spectrum 700 Power Supply: Install a
restrictor pin in any starter cartridge to be used with a Model SL60 or SL100 torch, according to the separate
instructions in Restrictor Pin Kit No. 8-3440 included with this Adapter Kit.
7. Reinstall any covers removed (see WARNING).
WARNING
Make sure that the Control Connector Wires DO NOT contact the Pilot Wire after all leads are connected.
8. Install the proper torch consumables per the Torch Instruction Manual.
9. Reconnect main input power to the Power Supply and turn the unit ON.
10. Set gas pressure and flow per the Torch Instruction Manual.
11. Test torch for proper operation.