Tweco 7-3433 Manuel d'utilisation

Page 2

Advertising
background image

January 16, 2004 / 16 Janvier, 2004

2

Manual / Manuel 0-2759

4. Connect the Control Connector Wires (see NOTE), with two connectors, to the two mating connectors on the

replacement torch leads.

Torch Control

Connectors

Pilot Lead

Torch Lead

Assembly

Negative/Plasma Lead

Art # A-03840

Control Connector

Wires with Connectors

To

Po

wer Supply

(-) Fitting

To

Po

wer Supply

Te

rm

inal C

onnections

To

Po

wer Supply

Pilot C

onnector

Spade Lugs

Not Present in

All Applications

NOTE

For Mechanized Systems refer to the Torch Control Cable Wiring Diagram on the last page of this Manual.

5. All Applications: Connect the spade lugs of the Control Connector Harness Wires to the Power Supply as

follows:

Wire No.

Terminal No.

1
2

3

3

4

4

1 (Jumper Wire)

6. When connecting a Model SL60 or SL100 torch to a Spectrum 500 or Spectrum 700 Power Supply: Install a

restrictor pin in any starter cartridge to be used with a Model SL60 or SL100 torch, according to the separate
instructions in Restrictor Pin Kit No. 8-3440 included with this Adapter Kit.

7. Reinstall any covers removed (see WARNING).

WARNING

Make sure that the Control Connector Wires DO NOT contact the Pilot Wire after all leads are connected.

8. Install the proper torch consumables per the Torch Instruction Manual.

9. Reconnect main input power to the Power Supply and turn the unit ON.

10. Set gas pressure and flow per the Torch Instruction Manual.

11. Test torch for proper operation.

Advertising