WARNING
Replacing Original Machine Torch with TDC RPT Mechanized Torch
Thermal Dynamics RPT mechanized torches have two control wires that are
used for Parts-In-Place, PIP, only. Do not connect these PIP connections di-
rectly into any start input because when the torch parts are in place, the start
signal will always be energized. If the torch parts are not in place but are subse-
quently installed with the start signal energized, the shield cup will complete the
start circuit and the unit will immediately transfer a pilot arc.
Torch Control Cable Wiring Diagram For Mechanized Systems Without
Quick Disconnect
Parts-In-Place (PIP)
Torch Control Connectors
Torch Lead
Assembly
Art # A-03843
Control Connector
Wires with Connectors
To Power Supply
Control Connections
(Start Signal)
Remote Start
Command
Torch Control
Cable
Not Present in
all Applications
Torch Control Cable Wiring Diagram For Mechanized Systems With Quick
Disconnect
Parts-In-Place (PIP)
Torch Control Wires
Quick Disconnect
Assembly
Art # A-02846
To Power Supply
Control Connections
(Start Signal)
Remote Start
Command
Torch Control
Cable
Existing Power Supply Wires
For Start Signal
Part of Control Connector
Wire with Connector Removed
In-Line Splice
Part of Control Connector
Wire with Connector
NOTE