Tweco 7-3430 Manuel d'utilisation

Page 4

Advertising
background image

January 16, 2004 / 16 Janvier, 2004

4

Manual/Manuel 0-2763

WARNING

Replacing Original Machine Torch with TDC RPT Mechanized Torch

Thermal Dynamics RPT mechanized torches have two control wires that are
used for Parts-In-Place, PIP, only. Do not connect these PIP connections di-
rectly into any start input because when the torch parts are in place, the start
signal will always be energized. If the torch parts are not in place but are subse-
quently installed with the start signal energized, the shield cup will complete the
start circuit and the unit will immediately transfer a pilot arc.

Torch Control Cable Wiring Diagram For Mechanized Systems Without

Quick Disconnect

Parts-In-Place (PIP)

Torch Control Connectors

Torch Lead

Assembly

Art # A-03843

Control Connector

Wires with Connectors

To Power Supply

Control Connections

(Start Signal)

Remote Start

Command

Torch Control

Cable

Not Present in

all Applications

Torch Control Cable Wiring Diagram For Mechanized Systems With Quick

Disconnect

Parts-In-Place (PIP)

Torch Control Wires

Quick Disconnect

Assembly

Art # A-02846

To Power Supply

Control Connections

(Start Signal)

Remote Start

Command

Torch Control

Cable

Existing Power Supply Wires

For Start Signal

Part of Control Connector

Wire with Connector Removed

In-Line Splice

Part of Control Connector

Wire with Connector

NOTE

Every effort has been made to provide complete and accurate information in this manual. However, the
publisher does not assume and hereby disclaims any liability to any party for any loss or damage caused
by errors or omissions in this manual, whether such errors result from negligence, accident or any other
cause.