INSTALLATION Continued

Adjustments

NOTE: Each oven has been factory tested and adjusted prior

to shipment. It may be necessary to further adjust the oven

as part of a proper installation. Such adjustments are the

responsibility of the installer. Adjustments are not considered

defects in material and workmanship, and they are not

covered under the original equipment warranty.

Lighting

1. Turn on main gas valve. Remove the lower front

cover and the service panel above the control panel.

Drop the control panel and leak test all fittings and

connections upstream from the service valve located on

the redundant combination gas valve. Should any gas

leaks be detected, turn OFF main gas valve, correct the

problem and retest.

2. Open shutoff valve located on the redundant

combination gas valve. Activate control panel and set to

desired temperature. The burners are ignited by direct

spark. Check all fittings again and correct any leaks and

recheck.

Replace all service panels and covers before operation.

NOTE: All electronic ignition systems are supplied with a

redundant gas valve. Therefore, the unit is not supplied with

an external pressure regulator.

NOTE: During installation there will be air in the gas line. This

air will have to bleed off before ignition can be established.

The electronic ignition system has a ninety second lock-out

as a safety device on all units. Therefore, several attempts

may be required before pilot ignition is established, wait five

minutes after each attempt.

FOR YOUR SAFETY: KEEP YOUR APPLIANCE ARE FREE FROM

COMBUSTIBLES.

To Conserve Energy

Do not waste energy by leaving controls at high temperature

settings during idle periods. Lower settings will keep

oven warm and ready for next use period. Summit 40

Series controls have an auto setback feature that is user

programmable to help with these applications.

TESTING AND ADJUSTMENTS

Termination Less than 10 feet (3 meters) from ridge

Termination More than 10 feet (3 meters) from ridge

Less than 10 feet (3 meters)

More than 10' (3 meters)

2' (60cm)

Min.

3' (90cm) Min.

3' (90cm) Min.