Installation – Doyon SRO2 Manuel d'utilisation

Page 11

Advertising
background image

FAM SROxG rev 07-13.doc

10/13

INSTALLATION


Take off the packaging material with care. Take off all the material used for packing and accessories.
Seal the unit on the floor with silicone. Verify every adjustments and correct it if necessary. Install
the hood covering the top front of the oven.

Each unit is set up to be used with the type of gas and electrical supply specified on the nameplate
fixed on the oven.

The installation must be conform with National fuel gas code ANSI Z223.1-XX and CAN/CGA-
B149-XX, Gas installation Code and local Codes where applicable. Refer to last edition year for
XX.

The oven's combustion system consists of a very safe gas burner certified in accordance to the
American Gas Association Standard in USA and with the Canadian Gas Association in Canada.

1. To the certified gas technician

The burner installed on DOYON gas fired ovens is set up and adjusted at the plant for a first class
operation. It is nevertheless necessary to verify on site the pressure at the burner input. The
following table indicates the pressures that must be set up to remain conform to the AGA standards
or CGA.

SRO1G

GAS

TYPE

ALTITUDE

(FT)

INPUT

(BTU)

EACH
OVEN

SECTION

REGULATOR

INPUT

PRESSURE

(Water column

inches)

REGULATOR

OUTPUT

PRESSURE

(Water column

inches)

MANIFOLD

PRESSURE

(Water column

inches)

BURNER
ORIFICE

SIZE (DMS)

QTY=26)

Propane

0-2000

175 000

11.0

8.6

8.5

# 66 drill

Propane

2000-4500

175 000

11.0

8.6

8.5

# 66 drill

Natural

0-2000

175 000

7.0

3.4

3.3

# 53 drill

Natural

2000-4500

175 000

7.0

3.4

3.3

# 53 drill

SRO2G

GAS

TYPE

ALTITUDE

(FT)

INPUT

(BTU)

EACH
OVEN

SECTION

REGULATOR

INPUT

PRESSURE

(Water column

inches)

REGULATOR

OUTPUT

PRESSURE

(Water column

inches)

MANIFOLD

PRESSURE

(Water column

inches)

BURNER
ORIFICE

SIZE (DMS)

QTY=26)

Propane

0-2000

275,000

11.0

7.6

7.3

# 60 drill

Propane

2000-4500

275,000

11.0

7.6

7.3

# 60 drill

Natural

0-2000

275,000

7.0

3.4

2.75

# 52 drill

Natural

2000-4500

275,000

7.0

3.4

2.75

# 52 drill

The burner used is adjusted for use with the gas indicated on the nameplate. It is nevertheless
possible to convert the burner to another gas by doing the modifications indicated in the
CONVERSION PROCEDURE provided with the oven. These modifications must be done carefully
and completely under the company's instruction to remain conform to A.G.A. or C.G.A standards.
Refer to Doyon Equipment to get the right CONVERSION KIT.

A-7

Advertising