Regulatory information, Contact information – Edwards Signaling Genesis WG4 Outdoor Horn-Strobe Manuel d'utilisation
Page 4

4 / 10
P/N 3102000-ML • REV 1.0 • ISS 11APR12
Table 4: Sound level output (dBA), per UL 464
Volume Setting
16V
24V
33V
Continuous High
89.7
94.7
97.4
Continuous Low
85.4
89.5
92.5
Temporal High
84.2
90.5
93.5
Temporal Low
81.7
85.4
88.1
dBA = Decibels, A-weighted.
UL 464: Sound level output measured in a reverberant room at 10 ft.
(3.05m).
Table 5: Sound level output (dBA), per CAN/ULC-S525
Volume setting
16V
24V
33V
Continuous High
94.0
99.6
102.9
Continuous Low
92.8
97.2
98.6
Temporal High
96.5
100.5
104.2
Temporal Low
90.3
94.2
97.0
dBA = Decibels, A-weighted.
CAN/ULC-S525: Sound level output measured in an anechoic room at
10ft (3.05m).
Table 6: Directional sound characteristics (horizontal pattern), per
CAN/ULC-S525
Angle (°) [1]
Sound output (dBA)
90 (Ref)
0 (Ref)
60 and 115
−3
45 and 132
−6
[1] Angles are measured from a perpendicular axis; positive angles to
the right.
Table 7: Directional sound characteristics (vertical pattern) , per
CAN/ULC-S525
Angle (°) [1]
Sound output (dBA)
90 (Ref)
0 (Ref)
80 and 110
−3
39 and 125
−6
[1] Angles are measured from a perpendicular axis; positive angles are
up.
Table 8: Indoor strobe output (candela)
Lens
Standard
D C B A
Clear
UL
1971
15 29 70 87
Table 9: Outdoor strobe output (candela at −35°C)
Lens
Standard
D C B A
Clear
UL
1638
6 12 28 35
Table 10: Outdoor strobe output (candela at −40°C)
Lens
Standard D
C B A
Clear
CAN/ULC-S525
1
3 8 10
Table 11: Horn-strobe operating current in RMS (A), continuous
Setting D C B A
16 to 33 VDC
127
168
297
351
16 to 33 VFWR
218
239
393
422
24
VDC 107 130 210 238
24
VFWR 190 222 325 356
Regulatory information
Manufacturer
Edwards, A Division of UTC Fire & Security
Americas Corporation, Inc.
8985 Town Center Parkway, Bradenton, FL
34202, USA
Year of
manufacture
The first two digits of the DATE MFG number
(located on the product identification label) are
the year of manufacture.
UL/ULC rating
Horn-Strobe: Regulated 24 DC and 24 FWR.
This device was tested to the regulated 24
DC/FWR operating voltage limits of 16 V and
33 V. Do not apply 80% and 110% of these
values for system operation.
FCC compliance
This device complies with part 15 of the FCC
Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any
interference received, including interference that
may cause undesired operation.
ICES compliance
This Class B digital apparatus complies with
Canadian ICES-003.
Environmental
class
Indoor and outdoor
Synchronization
Meets UL 1971 and ULC S526 requirements.
Maximum allowed resistance between any two
devices is 20 Ω. Refer to specifications for
compatible synchronization sources, this strobe,
and the control panel to determine allowed wire
resistance.
Agency listings
UL 1971, UL 1638, UL 464, CAN/ULC-S525,
CAN/ULC-S526
Contact information
For contact information see www.utcfireandsecurity.com.