If your outlet looks like this:

3-wire receptacle (10-30R)

Then choose a 3-wire power supply cord with ring or spade terminals and UL listed strain

relief. The 3-wire power supply cord, at least 4 ft (1.22 m) long, must have three 1 0-gauge
copper wires and match a 3-wire receptacle of NEMA Type 10-30R.
If connecting by direct wire:

Power supply cable must match power supply (4-wire or 3-wire) and be:

■ Flexible armored cable or nonmetallic sheathed copper cable (with ground wire),

protected with flexible metallic conduit. All current-carrying wires must be insulated.

■ 1 0-gauge solid copper wire (do not use aluminum).

■ At least 5 ft (1.52 m) long.

Electrical Requirements - Canada Only

GROUNDING INSTRUCTIONS

■ For a grounded, cord-connected dryer:

This dryer must be grounded. In the event of malfunction or

breakdown, grounding will reduce the risk of electric shock
by providing a path of least resistance for electric current.

This dryer uses a cord having an equipment-grounding
conductor and a grounding plug. The plug must be plugged

into an appropriate outlet that is properly installed and
grounded in accordance with all local codes and ordinances.

■ For a permanently connected dryer:

This dryer must be connected to a grounded metal,

permanent wiring system, or an equipment-grounding
conductor must be run with the circuit conductors and
connected to the equipment-grounding terminal or lead on

the dryer.

WARNING:

Improper connection of the equipment­

grounding conductor can result in a risk of electric shock.
Check with a qualified electrician or service representative
or personnel if you are in doubt as to whether the dryer is
properly grounded. Do not modify the plug on the power
supply cord: if it will not fit the outlet, have a proper outlet
installed by a qualified electrician.

SAVE THESE INSTRUCTIONS

AWARNING

Electrical Shock Hazard

Plug into a grounded 4 prong outlet.

Failure to do so can result in death or electrical shock.

It is your responsibility

■ To contact a qualified electrical installer.

■ To be sure that the electrical connection is adequate and in conformance with the

Canadian Eilectrical Code, C22.1 -latest edition and all local codes. A copy of the above
codes standard may be obtained from: Canadian Standards Association, 1 78 Rexdale

Blvd., Toronto, ON M9W 1 R3 CANADA.

■ To supply the required 4 wire, single phase, 120/240 volt, 60 Hz., AC only electrical

supply on a separate 30-amp circuit, fused on both sides of the line. A time-delay fuse
or circuit breaker is recommended. Connect to an individual branch circuit.

■ This dryer is equipped with a CSA International Certified Power Cord intended to be

plugged into a standard 14-30R wall receptacle. The cord is 5 ft (1.52 m) in length.

Be sure wall receptacle is within reach of dryer's final location.

4-wire receptacle I4-30R

■ Do not use an extension cord.

If you are using a replacement power supply cord, it is recommended that you use Power

Supply Cord Replacement Part Number 9831 31 7. For further information, please reference
the service numbers located in the "Assistance or Service" section.