Sun Microsystems 806-2989-10 Manuel d'utilisation
Page 75

Appendix B
Diagnostic Software and Troubleshooting Issues
55
4. Type
show-nets
to display the list of devices.
You should see a list of devices, similar to the example below, specific to the adapter:
5. Type the following to run the self-test using the
test
command:
The following tests are run when the
test
command is executed:
■
ce
register test
■
serdes internal loopback test
■
link up/down test
If the
test
passes, you see these messages:
If the card is not connected to a network, you see the following messages:
6. For more robust test results, set the
diag-switch?
to
true
and reissue the tests
as shown in Step 5 above.
ok show-nets
a) /pci@1f,0/pci@1/network@4
b) /pci@1f,0/pci@1,1/network@1,1
q) NO SELECTION
Enter Selection, q to quit:
ok test
device path
ok test /pci@1f,0/pci@1/network@4
ce register test --- succeeded.
Internal loopback test -- succeeded.
Link is -- up
ok test /pci@1f,0/pci@1/network@4
ce register test --- succeeded.
Internal loopback test -- succeeded.
Link is -- down
ok
ok setenv diag-switch? true