Venting, Warning, Venting requirements – Maytag W10296136A-SP Manuel d'utilisation
Page 8

8
Dryer gas pipe
The gas pipe that comes out through the rear of your dryer
■
has a 3/8" male pipe thread.
29" Wide model
A
1¼"
(32 mm)
9¼"
(235 mm)
A. 3/8" NPT dryer pipe
27" Wide model
A
*6¼"
(159 mm)
1½"
(38 mm)
A. 3/8" NPT dryer pipe
A. 3/8" NPT dryer pipe
Burner input requirements
Elevations up to 10,000 ft. (3,048 m):
The design of this dryer is certified by CSA International for
■
use at altitudes up to 10,000 ft. (3,048 m), above sea level at
the B.T.U. rating indicated on the model/serial number plate.
Burner input adjustments are not required when the dryer is
operated up to this elevation.
Elevations above 10,000 ft. (3,048 m):
When installed above 10,000 ft. (3,048 m) a 4% reduction
■
of the burner B.T.U. rating shown on the model/serial
number plate is required for each 1,000 ft. (305 m)
increase in elevation.
gas supply pressure testing
The dryer must be disconnected from the gas supply piping
■
system during pressure testing at pressures greater than
1/2 psi.
venting Requirements
WARNING
Fire Hazard
use a heavy metal vent.
Do not use a plastic vent.
Do not use a metal foil vent.
Failure to follow these instructions can result in death
or fire.
vEnTIng
WARnIng:
To reduce the risk of fire, this dryer MUST BE
EXHAUSTED OUTDOORS.
ImPoRTAnT:
Observe all governing codes and ordinances.
Dryer exhaust must not be connected into any gas vent,
chimney, wall, ceiling, attic, crawlspace, or a concealed space
of a building.
If using an existing vent system
Clean lint from the entire length of the system and make sure
■
exhaust hood is not plugged with lint.
Replace any plastic or metal foil vent with rigid heavy metal
■
vent or flexible metal vent.
Review Vent system chart. Modify existing vent system if
■
necessary to achieve the best drying performance. Only rigid
or flexible metal vent shall be used for exhausting.
If this is a new vent system
vent material
Use a heavy metal vent. Do not use plastic or metal foil vent.
■
4" (102 mm) heavy metal exhaust vent and clamps must be
■
used. DURASAFE™ venting products are recommended.
4" (102 mm) heavy metal exhaust vent
DURASAFE™ vent products can be purchased by calling
the toll-free number. For further information, please reference
the “Assistance or Service” section of the “Dryer User
Instructions.”
Rigid metal vent:
For best drying performance, rigid metal vents are
■
recommended.
Rigid metal vent is recommended to avoid crushing and
■
kinking.
Flexible metal vent:
Flexible metal vents are acceptable only if accessible for
■
cleaning.