Special provisions for mobile home installations
The exhaust vent must be securely fastened to a noncombustible portion of the mobile home
structure and must not terminate beneath the mobile home. Terminate the exhaust vent
outside.

Determine vent path

Select the route that will provide the straightest and most direct path outdoors.

Plan the installation to use the fewest number of elbows and turns.

When using elbows or making turns, allow as much room as possible.

Bend vent gradually to avoid kinking.

Use the fewest 90° turns possible.

Determine vent length and elbows needed for best drying performance

Use the following Vent system chart to determine type of vent material and hood
combinations acceptable to use.

NOTE: Do not use vent runs longer than those specified in the Vent system chart.

Exhaust systems longer than those specified will:

Shorten the life of the dryer.

Reduce performance, resulting in longer drying times and increased energy usage.

The Vent system chart provides venting requirements that will help to achieve the best drying
performance.

Vent system chart

NOTE: Performance of rear exhaust to either side of the dryer is equivalent to adding one
elbow. To determine maximum exhaust length, add one elbow to the chart.
NOTE: Bottom exhaust performance is equivalent to adding two elbows. To determine
maximum exhaust length, add one elbow to the chart.

Number of

90º turns

or elbows

Type of

vent

Box or

Louvered

hoods

Angled

hoods

0

Rigid metal

Flexible metal

100 ft (30.5 m)

72 ft (21.9 m)

94 ft (28.7 m)

64 ft (19.5 m)

1

Rigid metal

Flexible metal

90 ft (27.4 m)

67 ft (20.4 m)

84 ft (25.6 m)

59 ft (18 m)

2

Rigid metal

Flexible metal

80 ft (24.4 m)

63 ft (19.2 m)

74 ft (22.6 m)

55 ft (16.8 m)

3

Rigid metal

Flexible metal

71 ft (21.6 m)

61 ft (18.6 m)

65 ft (19.8 m)

53 ft (16.2 m)

4

Rigid metal

Flexible metal

63 ft (19.2 m)

59 ft (18 m)

57 ft (17.4 m)

51 ft (15.5 m)

Install Vent System

1. Install exhaust hood. Use caulking compound to seal exterior wall opening around

exhaust hood.

2. Connect vent to exhaust hood. Vent must fit inside exhaust hood. Secure vent to exhaust

hood with 4" (10.2 cm) clamp.

3. Run vent to dryer location. Use the straightest path possible. See “Determine vent path” in

“Plan Vent System.” Avoid 90º turns. Use clamps to seal all joints. Do not use duct tape,
screws or other fastening devices that extend into the interior of the vent to secure vent.

Install Leveling Legs

WARNING

Excessive Weight Hazard

Use two or more people to move and install dryer.

Failure to do so can result in back or other injury.

1. To protect the floor, use a large, flat piece of cardboard from the dryer carton. Place

cardboard under the entire back edge of the dryer.