Location requirements, Warning, Vented models – Whirlpool 29 Inch Electric Dryer Owners Guide Manuel d'utilisation

Page 8: Parts needed (not supplied with dryer), Available accessories, Recommended installation clearances (dryer only)

Advertising
background image

8

Vented Models:

Vent Clamps, elbows, and vent work

Parts Needed (not supplied with dryer):

Additional parts may be required, depending on your installation.

Check local codes. Check existing electrical supply and venting.

See “Electrical Requirements” and “Venting Requirements” before

purchasing parts.
Mobile home installations require metal exhaust system hardware

available for purchase from the dealer from whom you purchased

your dryer. For further information, please refer to the Quick Start

Guide for service contact information.

Available Accessories:

Accessories and replacement parts are available for your model.

For ordering and contact information, please reference your Quick

Start Guide.

Location Requirements

WARNING

Explosion Hazard

Keep flammable materials and vapors, such as gasoline,

away from dryer.
Do not dry anything that has ever had anything

flammable on it (even after washing).
Place dryer at least 18 inches (460 mm) above the floor

for a garage installation.
Failure to do so can result in death, explosion, or fire.

Check code requirements. Some codes limit, or do not permit,

installing dryer in garages, closets, mobile homes, or sleeping

quarters. Contact your local building inspector.

You will need:

For vented models:

A location allowing for proper exhaust

installation. See “Venting Requirements.”

A separate 30 A circuit for electric dryers.

If you are using power supply cord, a grounded electrical outlet

located within 2 ft (610 mm) of either side of dryer. See

“Electrical Requirements.”

A sturdy floor to support dryer weight of 200 lbs (90.7 kg).

Also, consider the combined weight of the companion

appliance.

For steam dryers:

Cold water faucets located within

4 ft (1.2 m) of the water fill valves, and water pressure of

20–120 psi (138–827 kPa). You may use the water supply for

your washer using the necessary parts as noted (which you

may need to purchase).

Level floor with a maximum slope of 1" (25 mm) under the

entire dryer. If the slope is greater than 1" (25 mm), install

Extended Dryer Feet Kit. If not level, clothes may not tumble

properly and automatic sensor cycles may not operate

correctly.

For garage installation, place dryer at least 18" (460 mm)

above the floor. If using a pedestal, you will need 18" (460 mm)

to bottom of the dryer.

The dryer must not be installed or stored in an area where it

will be exposed to water and/or weather.

IMPORTANT:

Do not operate dryer at temperatures below

45°F (7°C). Lower temperatures may cause dryer not to shut off at

end of automatic sensor cycles, resulting in longer drying times.

Installation clearances:

For each arrangement, consider allowing more space for ease of

installation and servicing, spacing for companion appliances, and

clearances for walls, doors, and floor moldings. Space must be

large enough to allow the dryer door to fully open. Add spacing on

all sides of the dryer to reduce noise transfer. If a closet door is

used, top and bottom air openings are required. Louvered doors

with equivalent ventilation openings can be used.

Installation spacing for a recessed area or closet

All dimensions show recommended and minimum spacing

allowed.

Additional spacing should be considered for ease of

installation and servicing.

Additional clearances might be required for wall, door, floor,

moldings, dryer venting, and drain system.

Additional spacing should be considered on all sides of the

dryer to reduce noise transfer.

For closet installation with a door, minimum ventilation

openings in the top and bottom of the door are required for

vented models. Louvered doors with equivalent ventilation

openings are acceptable.

Companion appliance spacing should also be considered.

Recommended installation clearances (dryer

only):

*Recommended/Minimum spacing

1"

(25 mm)

6"/0"*

(152 mm/0 mm)

14" (maximum)

(356 mm)

3"

(76 mm)

3"

(76 mm)

48 in

2

(310 cm )

2

24 in

2

(155 cm )

2

1"/0"*

(25 mm/0 mm)

18" (minimum)

(457 mm)

Advertising
Ce manuel est liée aux produits suivants: