Power supply cord connection, Choose electrical connection type, Attach power supply cord strain relief – Whirlpool 29 Inch Electric Dryer Owners Guide Manuel d'utilisation

Page 12: Attach power supply cord to strain relief, Wire power supply connection, Prepare ground wire appliance installation, Connect neutral bond wire and neutral wire, Connect ground wire

Advertising
background image

12

3. Choose electrical connection type

Power supply cord 4-wire receptacle

(NEMA Type 14-30 R):

Refer

to

“4-Wire

Power

Supply

Connection”.

Then,

go

to

“Venting

Requirements.”

Power supply cord 3-wire receptacle

(NEMA Type 10-30 R):

Refer

to

“3-Wire

Power

Supply

Connection”.

Then,

go

to

“Venting

Requirements.”

4-wire direct connection:

Go

to

“Direct

Wire

Strain

Relief,”

then

“4-Wire

Direct

Wire

Connection,”

then,

go

to

“Venting

Requirements.”

3-wire direct connection:

Go

to

“Direct

Wire

Strain

Relief”,

then

“3-Wire

Direct

Wire

Connection,”

then,

go

to

“Venting

Requirements.”

NOTE:

If local codes do not permit connection of a cabinet-

ground conductor to neutral wire, go to “Optional 3-wire

Connection.” This connection may be used with either a

power supply cord or a direct wire connection.

Power Supply Cord Connection

Power Supply Cord Strain Relief

1.

Attach power supply cord strain relief

Remove the screws from a 3/4" (19 mm) UL-listed strain relief

(UL marking on strain relief). Put the tabs of the two clamp

sections (C) into the hole below the terminal block opening (B)

so that one tab is pointing up (A) and the other is pointing

down (D), and hold in place. Tighten strain relief screws just

enough to hold the two clamp sections (C) together.

2.

Attach power supply cord to strain relief

Put power supply cord through the strain relief. Be sure that

the wire insulation on the power supply cord is inside the

strain relief. The strain relief should have a tight fit with the

dryer cabinet and be in a horizontal position. Tighten the strain

relief against the power supply cord. Do not overtighten the

strain relief screws.

4-Wire Power Supply Connection

IMPORTANT:

A 4-wire connection is required for mobile homes

and where local codes do not permit the use of 3-wire

connections.

A.

4-wire

receptacle

(NEMA

type

14-30

R)

B.

4-prong

plug

C.

Ground

prong

D.

Neutral

prong

E. Spade terminals with

upturned ends

F. 3/4" (19 mm) UL-listed

strain relief

G. Ring terminals

3. Prepare ground wire appliance installation

Remove center terminal block screw (B). Remove neutral

bond wire (E) from green external ground conductor screw

(A).

4. Connect neutral bond wire and neutral wire

Connect neutral bond wire (E) and neutral wire (white or

center) (C) of power supply cord under center terminal block

screw (B). Tighten screw.

5. Connect ground wire

Connect ground wire (F) (green or bare) of power supply cord

under green external ground conductor screw (A). Tighten

screw.