Special provisions for mobile home installations:

Exhaust vent must be securely fastened to a noncombustible

portion of the mobile home and must not terminate beneath the

mobile home. Terminate exhaust vent outside.

Determine vent path:

Select route that will provide

straightest and most direct path

outdoors.

Plan installation to use fewest

number of elbows and turns.

When using elbows or making

turns, allow as much room as

possible.

Bend vent gradually to avoid

kinking.

Use as few 90° turns as

possible.

Determine vent length and elbows needed for best

drying performance:

Use following “Vent System Chart” to determine type of vent

material and hood combinations acceptable to use.

NOTE:

Do not use vent runs longer than those specified in

“Vent System Chart.” Exhaust systems longer than those

specified will:

Shorten life of dryer.

Reduce performance, resulting in longer drying times and

increased energy usage.

The “Vent System Chart” provides venting requirements that will

help achieve best drying performance.

Vent System Chart

Number of 90°

turns or elbows

Type of vent

Box/louvered or

Angled hoods

0

Rigid metal

64 ft (20 m)

1

Rigid metal

54 ft (16.5 m)

2

Rigid metal

44 ft (13.4 m)

3

Rigid metal

35 ft (10.7 m)

4

Rigid metal

27 ft (8.2 m)

NOTE:

Side and bottom exhaust installations have a 90º turn

inside the dryer. To determine maximum exhaust length, add one

90º turn to the chart.

Vent System Chart (Long Vent Models)

Number of 90°

turns or elbows

Type of vent

Box/louvered or

Angled hoods

0

Rigid metal

160 ft (48.8 m)

1

Rigid metal

150 ft (45.7 m)

2

Rigid metal

140 ft (42.7 m)

3

Rigid metal

130 ft (39.6 m)

4

Rigid metal

120 ft (36.6 m)

5

Rigid metal

110 ft (33.5 m)

To determine if your model has a long vent system, refer to the

type code located on the serial number plate in the inner door

well. Example: A Long Vent Model would be BJAV-NAT-

XXXXXXX-XXX or BWFB-NAT-XXXXXXX-XXX.

NOTE:

For long vent systems, use of box/louvered hoods will

improve venting regardless of length.

Additional Elbows

In cases in which the Installation Instructions do not address the

vent length for the specific number of elbows required for a

particular application, the following calculations may be used.

(The total vent system length includes all straight and curved

portions of the vent system):

For 90° elbows, reduce the allowable vent system length by

10 ft (3.05 m).

For 45° elbows, reduce the allowable vent system length by

6 ft (1.83 m).

For

example,

if

the

Installation

Instructions

state

that

a

dryer

is

allowed

40

ft

(12.2

m)

of

total

vent

length

with

two

90°

bends,

the

total

allowable

vent

length

would

be

reduced

by

20

ft

(6.0

m)

(from

40

ft

(

12.2

m

)

to

20

ft

(

6.0m

)

).

Install Vent System

1. Install exhaust hood

Install exhaust hood and use caulking compound to seal

exterior wall opening around exhaust hood.

2. Connect vent to exhaust hood

Vent must fit over the exhaust hood. Secure vent to exhaust

hood with 4" (102 mm) clamp. Run vent to dryer location

using straightest path possible. Avoid 90° turns. Use clamps

to seal all joints. Do not use duct tape, screws, or other

fastening devices that extend into interior of vent to secure

vent, because they can catch lint.

12"minimum

(305 mm)

12"minimum

(305 mm)