Chapter 4: Performance Features & Safety Precautions

Product Service 1-800-522-7658

24

Original instructions

9. Clean-Sweep™ air foil allows air to sweep the work surface for maximum

containment.

10. Streamlined corner posts provide maximum visibility and the flexibility

to add services; services are most easily added at the factory, because of the
PVC liner.

11. All hoods are factory-prepared for up to 7 service fixtures. Additional

fixtures are available only as a factory special. Liner hole drilling is
required to add another fixture in the field.

12. One duplex electrical receptacle is mounted on the right corner post.

Receptacles are factory-wired to hood single point junction box.
Additional electrical receptacles are available as factory or field installed.

13. PVC interior liner is seamless PVC with coved interior corners and

integral work surface.

14. Accessory Guardian™ Digital Airflow Monitor or Guardian Jr.

Monitor continuously monitors face velocity. An audio/visual alarm alerts
the user to low airflow conditions. The right corner post is factory
prepared to accommodate the Guardian Monitor (sold separately).

15. Optional Energy-Reducing A-Style Combination Sash Models. These

combination sashes allow the operator to use the hood with sashes either
half open vertically or horizontally to conserve energy. Optional sash stops
prevent raising the vertical sash above the half-open and fully closed
positions unless manually defeated by the operator.

16. Outside frame of epoxy-coated steel and galvanized steel is durable and

corrosion resistant.

17. Exhaust connection. The hood features 12" (12.75" OD pipe) PVC

exhaust connections sized to allow for a minimum static pressure loss
through the hood structure while providing a good transport velocity
through the exhaust system.

18. Solid hardboard support provided to support the integral PVC bottom.

19. Optional Ceiling Enclosure Kits are available for a decorative facade

between the hood and the ceiling.

20. Optional Sash Stops provide a means of controlling the operating height

of the sash.

21. Washdown control fixture. Located on the left hand side of the hood

superstructure, this valve controls the water flow to the integral washdown
spray nozzles. The nozzles are located behind the hood baffle and
washdown areas in the hood, which are inaccessible without removing the
baffle. The control fixture can also be set up to control the washdown
system used in your exhaust ductwork. To do this, connect the water line
from your external washdown system to the plugged connection provided
on the top of the internal washdown assembly. For additional washdown
valves and sizing, See Chapters 2 & 7.