49-7774

Installation Instructions

INST

ALLA

TION INSTRUCTIONS

Use the correct wall case

7KLVXQLW

is designed to be installed in a GE

$SSOLDQFHVSODVWLFRULQVXODWHGPHWDOZDOOFDVH7KLV

minimizes condensation from forming on the room side
of the case.

NOTE:

7KHUHDUHVHYHUDOH[WUDKROHVLQWKHXQLWVLGH

flanges for installation in wall cases other than GE

$SSOLDQFHV7RDYRLGGDPDJLQJWKHIODQJHLQVXODWLRQ

the installer should use an awl or other sharp tool to
puncture the insulation in the appropriate holes before
installing the attachment screws.

Use the correct outdoor grille

You should use the outdoor grilles shown on the

³(VVHQWLDO(OHPHQWV´ODEHORQWKHEDVHSDQ

,IDQH[LVWLQJJULOOHLVQRWUHSODFHGFDSDFLW\DQG

efficiency will be reduced and the unit may fail to
operate properly or fail prematurely. A deflector

NLW5$.PD\EHXVHGZLWKJULOOHVWKDWZHUHQRW
GHVLJQHGIRU\RXUQHZ*($SSOLDQFHV=RQHOLQHV
7KH5$.FRQWDLQVDLUGHIOHFWRUVDQGJDVNHWV
WKDWPRXQWWRWKHXQLWWRGLUHFWWKHKRWH[KDXVWDLU

away from the air intake to allow the unit to function
properly

. The grille must have a 65% minimum

free area (as calculated by ASHRAE).

See the

Architects and Engineers Data Manual for more
detailed information.

Any vertical deflectors in a non GE Appliances

H[LVWLQJUHDUJULOOHVKRXOGEHUHPRYHGWRGHFUHDVH

condenser air recirculation that can cause the unit

WR³VKRUWF\FOH´DQGOHDGWRSUHPDWXUHFRPSRQHQW

failure.

Use the correct power cord

/RFDOFRGHVPD\UHTXLUHWKHXVHRIDUFIDXOWRU
OHDNDJHFXUUHQWGHWHFWLRQGHYLFHVRQYROW

installations.

Replacing a ducted unit

New ducted installation:

,IWKLVXQLWLVWREHLQVWDOOHGLQDQHZGXFWHGDSSOLFDWLRQ

using a duct adapter kit, the kit must be installed before

WKHXQLWLVSODFHGLQWKHZDOOFDVH7KHLQVWDOODWLRQ

instructions are packed with the kit.

Duct kits available:

5$.
5$.%%

Existing ducted installation:

5HSODFHPHQWRIDQH[LVWLQJGXFWHGXQLWPD\UHTXLUH

different components. Request this information from
your sales representative.

Duct seals on existing

unit need to be removed and added to the new
unit.

Replacing 230/208 volt units:

6HHSDJH

Replacing 265 volt units:

6HHSDJH

When using a duct kit, you must always turn Mode
7 to ON “ ”

6HH0RGHLQVWUXFWLRQVRQSDJH

REPLACING AN EXISTING UNIT

Check the “Essential

(OHPHQWV´ODEHOIRU

important information.

Duct

Case

Mounting

plate

Duct Mode

Shown ON