Cus tomer suppor t – Louisiana Grills 73 Inch Freestanding Smart Wood Pellet Grill User Manual Manuel d'utilisation

Page 16

Advertising
background image

ENGLISH

16

LOUISIANA GRILLS

CUS

TOMER SUPPOR

T

Er-1 Error code

Grill probe is not making a
connection

Check for damage to the grill probe. Follow care and maintenance instructions if
dirty. If all appears in working order, check the connection to the digital control
centre. Unplug unit from power source. Remove hopper access panel (see electric
wire diagram for diagram). Locate the white wires of the grill probe. Disconnect the
spade connectors, then reconnect until it clicks. Replace the hopper access panel.

Er-2 Error code

Grill fails to perform
start-up cycle

Check proper positioning of cooking components. Check hopper for sufficient fuel
or if there is an obstruction in the feed system. Remove pellets and follow care
and maintenance instructions. Check grill probe. Confirm if actual temperature
is correct and accurate. Follow care and maintenance instructions if dirty. Check
igniter positioning and that it is heating up properly. In extreme cold, the grill may
require a second start. Turn grill off, wait, then turn on again. Check fan. Ensure it is
working properly. Follow care and maintenance instructions if dirty.

Grill will not stay lit

Er-H Error code

The unit has overheated,
possibly due to grease fire
or excess fuel

Unplug unit from power source and allow to cool. Follow care and maintenance
instructions. Remove ashes and unburnt pellets from burn grate and bottom of the
grill. Check burn grate for proper positioning. Check proper positioning of cooking
components. After maintenance, plug unit into power source and press the power
button to turn the unit on. If error code is still displayed, contact Customer Care.

Er-5 Error code

Fan is not making a
connection

Unplug unit from power source. Remove hopper access panel (see electric wire
diagram for diagram). Locate the blue and white wires of the fan. Check fan blades
for damage. Follow care and maintenance instructions if dirty. Disconnect the
spade connectors, then reconnect until it clicks. Replace the hopper access panel.
If error code is still displayed, contact Customer Care.

Er-6 Error code

Igniter is not making a
connection

Unplug unit from power source. Remove hopper access panel (see electric wire
diagram for diagram). Locate the red and white wires of the igniter. Disconnect the
single molex connector, then reconnect until it clicks. Replace the hopper access
panel. If error code is still displayed, contact Customer Care.

Er-7 Error code

Auger motor is not making a
connection

Unplug unit from power source. Remove hopper access panel (see electric wire
diagram for diagram). Locate the yellow and white wires of the auger motor. Check
auger motor and bracket for damage. Disconnect the spade connectors, then
reconnect until it clicks. Replace the hopper access panel. If error code is still
displayed, contact Customer Care.

Advertising