Thetford N1095 Series Installation Manual - Current Manuel d'utilisation
Page 9

Installation Manual 9
- If the design of the vehicle does not allow you to install a roof exhaust vent, install an upper
side-wall exhaust vent.
The refrigerator is 23.7 in. min. to 24.0 in. max. from the rear of the breaker
to the rear of the condenser [22] and 54.1 in. min. to 54.4 in. max. from the
bottom of the refrigerator to the bottom of the refrigerator condenser [23]
(See Art01678).
- Install the upper side-wall exhaust vent [24] (See Art01679 and Art01680).
- Make sure the distance [25] from the bottom of the enclosure to the top of the rough
opening for the upper exhaust vent is at least 62 inches.
- Align the upper exhaust vent horizontally above the lower intake vent [9] of the
refrigerator.
- To prevent stagnant hot air in the area above the refrigerator, install an aluminum or
galvanized steel sheet baffle [13] between the top of the refrigerator and the top of
the upper exhaust vent.
- Make sure there is less than 1/4 inch clearance between the baffle and the top
of the refrigerator [16] and that the baffle overlaps the refrigerator 1 inch or
less.
- Make sure that the baffle is against the wall of the vehicle at the top of the
upper exhaust vent and 1/4 inch or less from the top of the opening for the
upper exhaust vent [15].
- Make sure the baffle is the full width of the inside of the enclosure
- When using an upper side-wall exhaust vent:
- If the depth of the enclosure is more than 24 inches and less than 26 inches [27], install a bent aluminum or galvanized steel
sheet baffle [26] to the rear of the enclosure (See Art01679).
22
23
Art01678
Art01679
27
9
10
25
26
24
15 13
15
11
15
213
Art01680
27
17
10
9
18
25
21
24
15
13
15
11
15
213
NOTICE