Wire Size Chart - Table A
Recommended Copper Wire and Fuse Sizes
HP Rating of Single Phase Motors
Distance
from Motor to
Meter
1/2
3/4
1
0-50’
115V
230V
12 GA
14 GA
12 GA
14 GA
10 GA
14 GA
50-100’
115V
230V
12 GA
14 GA
12 GA
14 GA
10 GA
14 GA
100-150’
115V
230V
12 GA
14 GA
10 GA
14 GA
10 GA
12 GA
150-200’
115V
230V
12 GA
14 GA
10 GA
12 GA
8 GA
12 GA
200-300’
115V
230V
10 GA
14 GA
8 GA
12 GA
6 GA
10 GA
Fuse Size
115V
230V
Amps
20
15
Amps
20
15
Amps
30
15
Ventilation
Ventilation and drainage must be provided to
prevent damage to the motor from heat and
moisture.
Freezing
The pump and all piping must be protected from
freezing. If freezing weather is forecast, drain
pump or remove completely from the system.
Water Supply
The water source must be able to supply enough
water to satisfy the capacity of the pump and
water needs.
Suction Lift
Suction lift is the vertical distance from the
lowest level of the water to the pump intake. See
performance charts on page 2 and 3 to determine
how far your pump can lift water.
Horizontal Distance
The horizontal distance is the horizontal
measurement between the pump suction and the
water source. This distance may affect the ability
of the pump to operate. If it is over 100 feet, call
the manufacturer for assistance at
1-800-742-5044.
Pipe And Fittings
Use galvanized steel or NSF PW Schedule 40
PVC pipe and fittings. This material is designed
for water pressure and will seal against air and
water under pressure. Do Not Use: DWV fittings,
as these are designed for drains without pressure
and will not seal properly. (
Fig. 4)
CAUTION: The entire system must be
air and water tight for efficient operation and to
maintain prime.
Wire Size:
The wire size is determined by the distance from
the power source to the pump motor, and the
horsepower rating of the motor. See the wire chart
on below for proper wire size.
GENERAL PUMP INFORMATION (CONTINUED)
Tools required
PREPARATION
Pipe wrenches (2)
Wire strippers
Needle-nose pliers
Phillips screwdriver
Wire cutters
Adjustable wrench
Pipe tape
Pipe dope
Optional Parts For Assembly
(not included) (Fig 2)
Item Description
1
Ball Valve (plastic)
2
3/4 in. x 1/4 in. bushing (steel)
3
Pressure Gauge
4
Pump stand for tank
5
Well adapter for single pipe packer
installations (straight and right
angle shown)
NOTE: For a successful installation, take time to study your application for the correct pipe size and
appropriate fittings. The illustrations in these instructions will assist you with required and optional
fittings. Sch. 40 PVC plastic pipe and fittings were used in these instructions.
Before beginning installation of product, make sure all parts are present. If any part is missing
or damaged, do not attempt to assemble the product. Contact customer service for replacement
parts.
Estimated Installation Time: 2 hours.
IL1385
lıı
ılı
ııı
lıı
ılı
ııı
lııı
lııı
ılıı
ılıı
ıılııı
lııı
ılıı
ılıı
ıı
200
80
160
140
120
100
80
60
40
20
1
2
3
4
2
5
Parts You May Need For Assembly (Not
Included) (Fig. 1)
Item Description
1
1-1/4 In. union
2
1-1/4 in. adapter
3
1-1/4 in. elbow
4
3/4 in. union
5
1 in. adapter
6
1 in. x 3/4 in. reducer bushing
7
3/4 in. adapter
8
1 in. elbow
9
1-1/4 in. check valve
10
3/4 in. tee (plastic)
11
3/4 in. tee (steel)
12
3/4 in. x 3 in. nipple (steel)
13
3/4 in. plug (steel)
14
Foot valve
Electric cord strain relief
134349 Flow control package
1
IL1382
12
1
4
9
14
11
13
8
10
7
6
5
3
2