SAFETY INFORMATION
DANGER:
1. Always disconnect power source before performing
any work on or near the motor or its connected load.
If the power disconnect point is out-of-sight, lock it in
the open position and tag it to prevent unexpected
application of power. Failure to do so could result in
fatal electrical shock.
2. Do not handle the pump with wet hands or when
standing in water as fatal electrical shock could
occur. Disconnect main power before handling unit
for ANY REASON!
3. RISK OF ELECTRIC SHOCK. These pumps have not
been investigated for use in swimming pool areas.
WARNING:
1. Follow all local electrical and safety codes, as well
as the National Electrical Code (NEC) and the
Occupational Safety and Health Act (OSHA).
2. Replace damaged or worn wiring cord immediately.
3. Do not kink power cable and never allow the cable
to come in contact with oil, grease, hot surfaces, or
chemicals.
4. Wire motor to correct supply voltage - see motor
nameplate and wiring diagrams and check voltage of
power supply.
5. Unit must be securely and adequately electrically
grounded. This can be accomplished by wiring the
unit to a ground metal-clad raceway system or by
using a separate ground wire connected to the bare
metal of the motor frame or other suitable means.
6. This product contains chemicals known to the State
of California to cause cancer and birth defects or
other reproductive harm.
7. Hazardous Pressure! Install pressure relief valve
in discharge pipe. Release all pressure on system
before working on any component.
8. Do not use to pump flammable or explosive fluids
such as gasoline, fuel oil, kerosene, etc. Do not use
in flammable and/or explosive atmospheres.
CAUTION:
1. Protect the power cable from coming in contact with
sharp objects.
2. Be careful when touching the exterior of an operating
motor - It may be hot enough to be painful or cause
injury.
3. Make certain that the power source conforms to the
requirements of your equipment.
4. Do not run pump dry.
5. Pump and plumbing must be full of water before
startup.
6. Do not pump water which contains sand, mud, silt, or
debris
NOTE: Pumps with the “UL” Mark and pumps with
the “US” mark are tested to UL Standard UL778.CSA
certified pumps are certified to CSA Standard C22.2 No.
108. (CUS)
Typical Pump Setup
Convertible jet pumps are designed for use in these applications:
1. Shallow wells (0 - 25 ft. lift) where ejector bolts to pump (Fig. 1)
2. Deep wells where well ID is 4” or more and a two pipe ejector is installed in the well. (Fig. 2)
3. Deep wells where well ID is 2” or more and a single pipe (packer) ejector is installed in the well.
(Fig. 3)
GENERAL PUMP INFORMATION
IL1184
Water
Level
Suction
Lift
3/4 or 1 in.
Discharge
Pipe
Suction
Pipe See
Table B
Discharge
to Home
Pipe
Support
Foot Valve
Pressure
Pipe See
Table B
4 in. ID Well
Ejector
2
IL1187
Water Level
25 ft.
Max
Suction
Lift
3/4 or 1 in.
Discharge Pipe
1-1/4 in.
Suction
Pipe
Discharge
to Home
Pipe
Support
Foot Valve
1
Shallow Well Application
Deep Well Application for 4 in. Wells
IL0209
3/4 or 1 in.
Discharge
Pipe
Suction
Pipe See
Table B
Discharge
to Home
Pipe
Support
Foot Valve
2 in. ID Well
Deep Well Application for 2 in. Wells
3
IMPORTANT:
This jet pump is wired for either 115V or 230V. The label on the
pump will state whether pump is pre-wired for 115V or 230V.
To change pump voltage, see pump label diagram or page 18 in
these instructions.