Installation instructions, Electrical supply, Wiring requirements – Fulgor Milano 700 Series 30 Inch Single Electric Wall Oven Installation Instructions Manuel d'utilisation

Page 11

Advertising
background image

EN

7

Electrical supply

Before installing the oven have a qualified electrician verify

that your home is provided with adequate electrical service

and that the addition of the oven will not overload the branch

circuit on which it is to be installed.

A separate three-wire or four-wire single phase, 240 Volt, 60

Hz, or a 208 Volt, 60Hz branch circuit is required.

NOTE

: For use with 208 v, 60 hz supply voltage, see

connecting to 208 volt circuit.

For hook-up of the oven you will need to have an approved

junction box installed where it will be easily reached through

the front of the cabinet where the oven will be located. The

oven has 3 feet of conduit.

Allow two to three feet of slack in the line so that the oven can

be moved if servicing is ever necessary.

DO NOT shorten the flexible conduit.

LOCATION OF RATING PLATE

Wiring requirements

When making the wire connections, use the entire length of the

conduit provided (3 feet). The conduit must not be cut.

Before making connections make sure the power is off and

read and observe the following:

1. A separate three-wire or four-wire, single phase, 240 Volt,

60 Hz or 208 Volt, 60 Hz branch circuit is required for the

oven.

2. The oven must be connected with Copper or Aluminum wire.

3.

In the United States:

Wiring must conform to the National Electrical Code,

ANSI/NFPA No. 7 latest edition. You can obtain a copy

of the National Electrical Code by writing to: National

Fire Protection Association Batterymarch Park Quincy, MA

02269

In Canada:

Wiring must conform to Canadian Electrical Code C22.1-

latest edition. You can obtain a copy of the Canadian

Electrical Code by writing to: Canadian Standards

Association 178 Rexdale Boulevard Rexdale (Toronto),

Ontario, Canada M9W 1R3

4. Wire size (Copper or Aluminum wire) and connections must

be suitable for the rating of the appliance as per the National

Electrical Code requirements. The flexible armoured cable

extending from the oven should be connected directly to the

junction box.

5. The junction box should be located so as to allow as much

slack as possible between the junction box and the oven so

it can be moved if servicing is ever required.

6. A U.L. listed conduit connector must be provided at each

end of the power supply cable.

Installation Instructions

Advertising