Error codes – Fulgor Milano 400 Series 24 Inch Induction Cooktop User Manual Manuel d'utilisation
Page 15

EN
13
Error codes
Error codes are displayed by the 7-segment display with “E” or “ER” plus the error number.
Error message
Description
Possible error reason
Troubleshooting
“flash”
Control is detecting a button
being activated for more than 10
seconds.
Water or cooking utensils on
the glass above the control unit
Cleaning of the operational
surface
Er 22
Defective Key evaluation . Control
unit cuts off after 3.5 - “7.5 sec.
Short-circuit or no continuity in
the range of the key evaluation
Exchange control unit
Er20
Flash-failure
Faulty microcontroller
Exchange control unit
Er36
NTC value is not
within its specification
(value < 200mV or > 4.9V;
control unit cuts off
Short-circuit or cut-off at NTC
Exchange control unit
Er31
Configuration data incorrect
Configuration of induction
necessary
New Configuration
Er47
Communication error between TC
and induction
None or faulty communication! Ensure that connection cable
is plugged on correctly and
functional.
E2
Overheating of the induction coils
Cooling down necessary
U400
Secondary voltage of the power
unit too high (primary > 300V).
Control unit cuts off after 1 sec
releasing a permanent tone.
Control unit is wrongly
connected
Connect to correct mains
voltage
E5
No communication between
User Interface and Induction
Generator
Exchange Induction Generator
E6
Power supply voltage is out of
range (voltage and/or
frequency)
Exchange power unit
E9
Coil temperature sensor defective
Exchange temperature sensor