13

Error codes

Error codes are displayed by the 7-segment display with “E” or “ER” plus the error number.

Error message

Description

Possible error reason

Troubleshooting

“flash”

Control is detecting a button

being activated for more than 10

seconds.

Water or cooking utensils on

the glass above the control unit

Cleaning of the operational

surface

Er 22

Defective Key evaluation . Control

unit cuts off after 3.5 - “7.5 sec.

Short-circuit or no continuity in

the range of the key evaluation

Exchange control unit

Er20

Flash-failure

Faulty microcontroller

Exchange control unit

Er36

NTC value is not

within its specification

(value < 200mV or > 4.9V;

control unit cuts off

Short-circuit or cut-off at NTC

Exchange control unit

Er31

Configuration data incorrect

Configuration of induction

necessary

New Configuration

Er47

Communication error between TC

and induction

None or faulty communication! Ensure that connection cable

is plugged on correctly and

functional.

E2

Overheating of the induction coils

Cooling down necessary

U400

Secondary voltage of the power

unit too high (primary > 300V).

Control unit cuts off after 1 sec

releasing a permanent tone.

Control unit is wrongly

connected

Connect to correct mains

voltage

E5

No communication between

User Interface and Induction

Generator

Exchange Induction Generator

E6

Power supply voltage is out of

range (voltage and/or

frequency)

Exchange power unit

E9

Coil temperature sensor defective

Exchange temperature sensor