background image

Electrical Connection
(Non-Canada) - 3-wire
Cord

3-wire receptacle

(NEMA type 10-30R)

WARNING

ELECTRICAL SHOCK HAZARD

Failure to disconnect power source before
servicing could result in personal injury or
even death.

1. Turn off power supply to outlet.
2. Remove the three screws securing the

terminal block access cover in the upper
corner on the back of the dryer.

NOTE

Terminal screws were shipped from the factory
temporarily attached inside the access cover.

Installation Instructions

NOTE

Two cords shown above with different
terminal types.

Terminal Block Access Cover

1

1

30 AMP

NEMA 10-30

Neutral (center wire)

1

1

WARNING

ELECTRICAL SHOCK HAZARD

Do not make a sharp bend or crimp wiring/
conductor at connections.

WARNING

ELECTRICAL SHOCK HAZARD

DO NOT move internal ground in a 3-wire
system.

4. Attach the remaining two power cord

outer conductors to the outer, BRASS
colored terminals on the terminal block.
Tighten both screws securely.

3. Using an UNPLUGGED, UL-approved,

30 amp. power cord, NEMA 10-30 type
SRDT, attach the neutral (center wire)
conductor to the SILVER colored center
terminal on the terminal block. Tighten the
screw securely.

Neutral Silver Terminal

3

3

Outer Brass Terminals

4

4

4