English – Laerdal ALS Simulator (SimPad capable) Manuel d'utilisation
Page 11

9
After Use:
Cleaning
1 . Clean with mild soap and water; do not submerse the simulator or parts in
cleaning fluids or water .
2 . Use only on clean surface . Avoid felt tipped markers, ink pens, acetone, iodine
or other staining products and avoid placing the simulator on newsprint or
inked lines of any kind .
3 . To ensure longevity, each simulator should be cleaned after each training
session and a general inspection should be conducted regularly .
4 . Modules and all other parts should be drained and air-dried thoroughly
before storage and disinfected when needed . After use of injection pads
(use water only), accumulated water should be squeezed out .
NOTE: Do
not store wet foam pads in the skin . To prevent mildew or mold, pads can
be soaked in a mild solution of disinfectant and water or bleach and water .
Squeeze excess solution from pads, allow them to dry, then store or reinsert
in simulator .
5 . Articulating parts will benefit from a light application of talcum powder prior
to training sessions .
Extend Cleanliness
To extend the cleanliness of your simulator:
1 . Use a small towel and lightly dust the simulator head and chest with a small
amount of powder (provided) . Wipe away any excess .
2 . Use gloves when handling the simulator .
Laerdal Recommends
Use only on clean surface . Avoid felt tipped markers, ink pens, acetone,
iodine or other staining products and avoid placing the simulator on
newsprint or inked lines of any kind . These will stain the simulator .
Technical Data
General
Operating Temperature:
0°C – 40°C at 90% relative humidity, non-condensing
Storage Temperature:
-15°C – 50°C at 90% relative humidity, non-condensing
ALS Simulator
Defibrillation: Average of 720 J /minute max
Emergency Cardiac Capabilities
• Synchronized variable heart rate, rhythm, abnormalities and duration
• Defibrillation (25 -360 J)
IV Arm
Accessible veins include median, basilic and cephalic
Standards/Approvals
The product is in compliance with the essential
requirements of Council Directive 2004/108/EC on
electromagnetic compatibility (EMC) .
The product is in compliance with Council Directive
2011/65/EU on restriction of the use of certain
hazardous substances (RoHS) .
Minimum Computer Requirements
• Intel i-core generation 3 or newer
• Score over 3000 PassMark - CPU Mark
• 4 GB RAM
• 120GB hard disk space
• 1366x768 or better
• Headset w/microphone
• USB ports – 2
Minimum Software Requirements
• Windows 7 or Windows 8
• 100% DPI
Replacement Parts:
For latest version of Spare Parts and Accessories, visit www .laerdal .com
Photo 27
Table of Contents
Items Included. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Skills Taught. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Teeth . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Carotid Pulse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Tracheostomy Plug & Care. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
NG Tube Placement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Intubation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Lungs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Stomach Reservoir . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Belly Plates. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Injection Pads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Waist, Knee and Ankle Joints . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Arms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Legs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
IV Arm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Replacing Skin & Vein System. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Blood Pressure Arm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Auscultation of Heart, Breath, Bowel Sounds and Fetal Tones . . . . . . . . . . . . . . 4
Genitalia. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Colon Reservoir . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Urinary Catheterization and Enema Simulation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Attaching Nursing Anne Modules to Manikin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
SimPad Connection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Care and Maintenance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Replacement Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Items Included:
(1) Full-Body Female Manikin
(1) Articulating Blood Pressure Training Arm (Nursing Anne SimPad)
(1) Articulating Female Multi-Venous IV Training Arm
(1) Hospital Gown
(1) Male Genitalia
(1) Female Genitalia
(3) Urinary Valves
(3) Anal Valves
(1) Simulated Blood Concentrate
(1) 100 cc Syringe
(1) Manikin Lubricant
(1) Assembly Tool Kit
Wig pictured on front cover, not included
Optional Accessories
Nursing Anne Modules:
(1) Breast Exam Module, with interchangeable abnormalities
(1) Mastectomy Module with staples and drain
(1) Fundus Module with interchangeable uteri
Wound Care & Assessment Set:
(1) Abdominal Incision Module with Painted Sutures
(1) Abdominal Incision Module with Staples and Penrose Drain
(1) Abdominal Incision Module with Nylon Sutures
and Penrose Drain
(1) Abdominal Subcutaneous Heparin and Insulin Injection Module
(1) Abdominal Packing Module
(1) Infected Colostomy Stoma
(1) Ventro-Gluteal and Gluteal Decubitus Ulcer Modules
(1) Below Knee Amputation Stump
(1) Thigh Packing and Irrigation Module
(1) Thigh Suture Module
(1) Thigh Debridement Module
(1) Varicose Vein Leg with Stasis Ulcer
(1) Diabetic Foot Module
Skills Taught:
• Basic patient handling
• Denture care
• Oral hygiene
•
• Eye andear irrigation
(simulated)
• NG Tube insertion, care medication administration and removal
• Tracheostomy care and suctioning
• Blood pressure skills (When
used with
SimPad)
• IV care and management
• Subcutaneous and intramuscular injection
• Oxygen delivery procedures
• Ostomy irrigation and care
• Catheterization skills
• Enema simulation
• Colonic irrigation
• Wound assessment and care
• Bandaging and dressing
• Post-surgical mastectomy-care procedures
• Recognition of breast disorders, their sizes and relative locations
• Practice of fundus massage skills
• Auscultation and recognition of normal and abnormal heart,
breath and bowel sounds and fetal tones
(When used with SimPad)
Caution: Latex
This product contains Natural Rubber latex which may cause
allergic reactions when in contact with humans.
Please contact Laerdal Customer Service
for more information on Replacement Parts in other skin tones.
E
N
G
LI
SH
E
NGLISH
Nursing Anne
1
Laerdal
The product, when carrying the CE-mark, is in
compliance with essential CE requirements and other
relevant provisions of council directive 1999/5/EC.
• Lavage/Gavage
Oral and nasal Intubation
.
English