Precautions, Disassembling the camera, Setting the switches – Panasonic WV-CS554 Manuel d'utilisation
Page 48: Rs485 parameter setup
Attention! Le texte de ce document a été détectée automatiquement. Pour consulter le document original, vous pouvez utiliser le mode "Original".

— Precautions-----------------------------------------------------------------------------------------------------------------------------
• The following steps of installation and connection should be taken by qualified service personnel or
system installers and should conform to all local codes.
• Make sure to switch the camera off before installation and connection.
• Do not install the camera near the air outlet of an air conditioner.
1. Disassembling the Camera
(1) Loosen the fixing screw to separate the
camera mounting base and the camera.
Push up the screwdriver once before
removing the screw.
(2) Turn the camera mounting base ap
proximately 15 degrees counterclock
wise and remove the base from the
camera,
2. Setting the Switches
There are two DIP switches on the camera:
an 8-bit switch and a 4-bit switch. The 8-bit
DIP switch is used in both ways to return to
the factory default settings and to specify
the unit number. The 4-bit DIP switch
selects termination ON/OFF and half/full
duplex selection for RS485 communications.
Switch settings are read in to the camera
when the power is turned on. Make sure to
turn it off, then turn it back on after changing
the switch settings. Switch positions and
functions are shown below,
RS485 Parameter Setup
The selected protocol, communication para
meters, and set unit numbers are read into
the camera when power is switched on,
1, Switch off the camera,
2, Set the switch according to the function
shown in the table,
3, Switch on the camera to read in the
changed switch settings,
4, Switch off the camera,
5, Set the unit number with the DIP switch
(see next page),
6, Switch on the camera to read in the
changed switch settings.
Note:
The
changed
communication
parameters are displayed on the
RS485 SETUP menu after the cam
era has been switched on.
Turn 15
Remove
from the
camera
Camera
mounting base
Switch position
Returns to the factory default settings.
Switch position
Parameter selection
Baud rate
Data bit
Parity
check
Stop
bit
??????№
19 200
8
None
1
B
bsbbbbh
12 3 4 5
T T T
9 600
8
None
1
teBBBBBB
1 2 3 4 s e r a 4 8 0 0
8
None
1
48