Safety label, L'étiquette de sécurité – Regency Horizon HZI234E Small Gas Insert Manuel d'utilisation
Page 4

4
Regency
®
HZI234E Direct Vent Gas Insert
4
l'ÉTiqueTTe de sÉcuriTÉ
saFeTY label
Minimum Clearances to Combustibles from Insert
Side Walls
*A
8"
(203mm)
Ceiling
B
56"
(1422mm)
Min. Mantel Height
C
15.5"
(394mm)
Max. Mantel Depth
D
12"
(305mm)
Alcove Width
E
60"
(1524mm)
For installation in Solid Fuel Burning Fireplaces. This appliance must be installed in
accordance with local codes, if any. If none, follow the National Fuel Code, ANSI
Z223.1/NFPA 54 or Natural Gas and Propane Installation Codes, CSA B149.1. This
vented gas fireplace heater is not for use with air filters.
For Manufactured Home Installation: This Direct Vent System Appliance must be
installed in accordance with the manufacturer's installation instructions and
Manufactured Home Construction and Safety Standard Title 24 CFR, Part 3280, or the
current Standard for Fire Safety Criteria for Manufactured Home Installation, Sites, and
Communities ANSI/NFPA 501A, and with CAN/CSA Z240 MH Mobile Home Standard in
Canada.
This appliance is only for use with the type of gas indicated on the rating plate. See
owner's manual for details. For use with glass doors certified with the appliance only.
This appliance is not convertible for use with other gases, unless a certified kit is used.
This fireplace has been converted for use with a gas fireplace insert only
and cannot be used for burning wood or solid fuels unless all original parts have been
replaced, and the fireplace re-approved by the authority having jurisdiction. For use with
glass doors certified with the appliance only.
Installer l'appareil selon les codes ou règlements locaux, ou, en l'absence de tels
règlements, selon les codes d'installation ANSI Z223.1, National Fuel Gas Code ou
CSA-B149.1 en vigueur.
: Ce foyer a été converti pour utilisation avec un foyer au gaz
encastrable et ne peut être utiliser pour brûler du bois ou d'autres combustibles solides
à moins que toutes les pièces d'origine aient été remplacées et que le foyer ait été
approuvé de nouveau par l'autorité compétente
WARNING:
AVERTISSEMENT
Cet appareil d'évacuation directe doit être installé selons les instructions du fabricant et
conformément à la norme Manufactured Home Construction and Safety Standard, Title
24 CFR, Part 3280 ou les Standard of Fire Safety Criteria for Manufactured Home
Installations, Sites, and Communities ANSI/NFPA 501A, où la norme CAN/CSA Z240
Série MM, Maisons mobiles au Canada.
Cet appareil n'est pas convertible pour une utilisation avec d'autres gaz, sauf si un kit
certifié est utilisé.
DO NOT REMOVE THIS LABEL / NE PAS ENLEVER CETTE ETIQUETTE
Listed: VENTED GAS FIREPLACE HEATER
Tested to:
Certified for / Certifiée pour: CANADA AND U.S.A.
CAN/CGA-2.17-M91(R2009)
ANSI Z21.88-2009/CSA 2.33-2009
Serial No. / No de serie
381
`
NATURAL GAS FIREPLACE INSERT: MODEL HZI234E-NG
Factory Equipped For Altitude 0-4500ft. (0-1370m)
Min. Supply Pressure
5“
WC
(1.25 kpa)
Low Setting Man. Pressure
1.6"
WC
(0.40 kpa)
Max. Manifold Pressure
3.5"
WC
(0.87 kpa)
Orifice Size
48
DMS
Minimum Input
12,000
Btu/h
(
)
Maximum Input
16,500
Btu/h
(4.84 kW)
3.52 kW
D
E
F
A
B
C
381
Model/Modele:
HZI234E-NG
Model/Modele:
HZI234E-LP
918-987
PROPANE GAS FIREPLACE INSERT: MODEL HZI234E-LP
Factory Equipped For Altitude 0-4500ft. (0-1370m)
Min. Supply Pressure
11"
WC
(2.74 kpa)
Low Setting Man. Pressure
6.4"
WC
(1.59 kpa)
Max. Manifold Pressure
10"
WC
(2.49 kpa)
Orifice Size
56
DMS
Minimum Input
12,000
Btu/h (3.51 kW)
Maximum Input
15,000
Btu/h (4.40 kW)
FPI Fireplace Products International Ltd., Delta BC, CANADA
MADE IN CANADA / FABRIQUE AU CANADA
* Alcove side wall must have a min. of 8” (203mm)
clearance on one side.
Fan Part No. 910-331/P
Electrical Supply: 115 V, 56 WATTS, 60 Hz
NOT FOR USE WITH SOLID FUEL-NE PAS UTILISER AVEC DU
COMBUSTIBLE SOLIDE.
VENTED GAS FIREPLACE HEATER / FOYER AU GAZ À ÉVACUATION
4001172
Voici une copie de l’étiquette apposée sur chaque foyer
à gaz encastrable HZI234E afin de vous permettre d'en
examiner le contenu. Cette étiquette de sécurité se
trouve à l’intérieur de la base de l’appareil, à l’avant,
et est visible lorsque la grille d’aération inférieure est
ouverte.
REMARQUE: Nous améliorons constamment nos produits Regency
MD
.
Comparez cette copie avec l’étiquette apposée sur votre appareil. S’il
existe une différence, fiez-vous à cette dernière.