Installation continued – Garland THE MASTER HALF SIZE ELECTRIC CONVECTION OVEN Manuel d'utilisation
Page 6

Part # 260BGL Rev B (10/12/11)
Page 6
Ventilation
WARNING: Inadequate ventilation may result in a high
ambient temperature at the rear of the oven. Excessive
ambient temperature can cause tripping of the blower
motor’s thermal overload protection device. This condition
must be corrected immediately to avoid damage to the
blower motor.
IMPORTANT : Large objects should not be placed in front
of this oven, which would obstruct the airflow through the
front. Objects should not be placed on main top rear of oven
while in use. This could obstruct the venting system of the
units.
Electrical Connections
Before attempting the electrical connection, the rating
plate should be checked to ensure that the unit’s electrical
characteristics and the supply electrical characteristics agree.
THE ELECTRICAL POWER LINES MUST BE INSTALLED IN
ACCORDANCE WITH:
- The National Electrical Code, ANSI/NFPA No. 70 latest
edition (USA)
- Canadian Electrical Code, CSA C22.2
INSTALLATION Continued
- Any other applicable National, State or municipal codes and
regulations..
THE FOLLOWING CONDITIONS MUST BE ADDRESSED:
1. Switch panel size
2. Overload protection
3. Wire type
4. Wire size
5. Temperature limitations of the wires
6. Method of connection (Cable, Conduit, etc.)
The service line will enter through the rear of the unit and is
to be connected to the terminal block (see diagram below).
The terminal block is accessed by removing the right side
body panel.
Input voltage and phasing must match the units voltage
and phasing . Wiring diagram is attached to the main back of
each oven. Visually check all electrical connections. Energize
electric service to units. The range is wired standard for three
phase connections. If it is necessary to change to single
phase, please refer to wiring diagram attached to the rear of
the oven. Service and unit voltage must agree.