Napoleon Fireplaces Grandville 36 - BGD36 Manuel d'utilisation
Page 7

7
W415-0773 / F / 08.26.13
EN
2.4 GENERAL
INFORMATION
FOR YOUR SATISFACTION, THIS APPLIANCE HAS BEEN TEST-FIRED TO ASSURE ITS OPERATION AND
QUALITY!
GD36 RATES AND EFFICIENCIES
BGD36 RATES AND EFFICIENCIES
NG
LP
NG
LP
Altitude (FT)
0-4,500
0-4500
Altitude (FT)
0-4,500
0-4,500
Max. Input (BTU/
HR)
26,000
26,000
Max. Input
(BTU/HR)
18,000
17,000
Max. Output
(BTU/HR)
22,360
22,880
Max. Output
(BTU/HR)
11,500
10,900
Effi ciency
(w/the fan on)
86%
88%
Effi ciency
(w/the fan on)
64%
64%
A.F.U.E.
64%
65%
A.F.U.E.
53%
53%
Min. Inlet Gas
Supply Pressure
4.5" (11.2mb)
w.c.
11" (27.4mb)
w.c.
Min. Inlet
Gas Supply
Pressure
4.5" (11.2mb)
w.c.
11" (27.4mb)
w.c.
Max. Inlet Gas
Supply Pressure
7" (17.4mb)
w.c.
13" (32.4mb)
w.c.
Max. Inlet
Gas Supply
Pressure
7" (17.4mb)
w.c.
13" (32.4mb)
w.c.
Manifold
Pressure (Under
Flow Conditions)
3.5" (8.7mb)
w.c.
10" (25mb)
w.c.
Manifold
Pressure
(Under Flow
Conditions)
3.5" (8.7mb)
w.c.
10" (25mb)
w.c.
This appliance is approved for bathroom, bedroom and bed-sitting
room installations and is suitable for mobile home installation.
No external electricity (110 volts or 24 volts) is required for the
gas system operation.
Expansion / contraction noises during heating up and cooling
down cycles are normal and are to be expected.
66.4%
GD36