Warning, 0 installation – Napoleon Fireplaces Grandville 36 - BGD36 Manuel d'utilisation
Page 24

24
W415-0773 / F / 08.26.13
EN
4.3 BGD36 REAR EXIT
4.4 BGD36 TOP VENT
From inside the fi rebox, insert the 4" (102mm) fl ue pipe / gasket assembly (provided)
through the rear of the fi rebox. Secure the gasket assembly to the rear and top of the
appliance using 4 #8 x ¾ inch Hex Head Wildrill screws supplied.
Do not overtighten. The gasket needs only to be snug against the fi rebox.
Before attaching elbows to the collars on the back of the appliance, 1½" (38mm) will
need to be trimmed off the 4" (102mm) collar.
A.
Remove the 7" (178mm) diameter cap from the top of the appliance and
re-secure it over the 7" (178mm) collar located at the rear of the appliance.
Press fi rmly on the cap while securing to ensure an airtight seal. Do not
damage the gasket.
B.
Remove the plate covering the 4" (102mm) diameter fl ue opening (seen
inside the top of the 7" (178mm) diameter collar) and discard. Try not to
disturb the retaining ring or the gasket beneath. Re-secure the ring and
gasket using the screws removed from the plate.
C.
From inside the fi rebox, insert the 4" (102mm) fl ue pipe / gasket assembly through the heat shield and
out through the retaining ring. Secure the assembly to the rear and top of the appliance using 4 #8 x
¾" Hex Head Wildrill screws supplied. Do not overtighten. The gasket needs only to be snug against
the fi rebox.
5.0 INSTALLATION
!
WARNING
ENSURE TO UNPACK ALL LOOSE MATERIALS FROM INSIDE THE FIREBOX PRIOR TO HOOKING UP
THE GAS AND ELECTRICAL SUPPLY.
IF YOUR APPLIANCE IS SUPPLIED WITH A REMOTE ENSURE THE REMOTE RECEIVER IS IN THE
“OFF” POSITION PRIOR TO HOOKING UP THE GAS AND ELECTRICAL SUPPLY TO THE APPLIANCE.
FOR SAFE AND PROPER OPERATION OF THE APPLIANCE, FOLLOW THE VENTING INSTRUCTIONS
EXACTLY.
ALL INNER EXHAUST AND OUTER INTAKE VENT PIPE JOINTS MAY BE SEALED USING EITHER RED
RTV HIGH TEMP SILICONE SEALANT W573-0002 (NOT SUPPLIED) OR BLACK HIGH TEMP MILL PAC
W573-0007 (NOT SUPPLIED) WITH THE EXCEPTION OF THE APPLIANCE EXHAUST FLUE COLLAR
WHICH MUST BE SEALED USING MILL PAC.
IF USING PIPE CLAMPS TO CONNECT VENT COMPONENTS, 3 SCREWS MUST ALSO BE USED TO
ENSURE THE CONNECTION CANNOT SLIP OFF.
DO NOT CLAMP THE FLEXIBLE VENT PIPE.
RISK OF FIRE, EXPLOSION OR ASPHYXIATION. IMPROPER SUPPORT OF THE ENTIRE VENTING
SYSTEM MAY ALLOW VENT TO SAG AND SEPARATE. USE VENT RUN SUPPORTS AND CONNECT
VENT SECTIONS PER INSTALLATION INSTRUCTIONS.
RISK OF FIRE, DO NOT ALLOW LOOSE MATERIALS OR INSULATION TO TOUCH THE VENT PIPE.
REMOVE INSULATION TO ALLOW FOR THE INSTALLATION OF THE ATTIC SHIELD AND TO
MAINTAIN CLEARANCES TO COMBUSTIBLES.
68.2B