Napoleon Fireplaces Grandville 36 - BGD36 Manuel d'utilisation
Page 39

39
W415-0773 / F / 08.26.13
EN
APPLIANCE
RECESS OR
ALCOVE
AREA
NOTE: Recesses or alcoves above the appliance can be made as deep as desired provided the minimum
clearances to combustibles are maintained.
Non-combustible material can be used, provided the minimum clearances to combustible materials are applied.
The minimum enclosure volume must be increased by no less than the volume of the recess. This adjustment
can be made by increasing any or all of the height, width and depth of the enclosure.
71.2
ENCLOSURE
AREA
6.4 ALCOVE
CLEARANCES
2" 51mm
1"
25mm
24" 610mm
MINIMUM
PLUS RISE*
2" 51mm
COMBUSTIBLE NON-COMBUSTIBLE
BRICK
0” (0MM) IF
NON-COMBUSTIBLE
FINISHING IS USED
SUCH AS BRICK
AND STONE.
39"
991mm
6" 152mm
MINIMUM
2" 51mm
1"
25mm
2" 51mm
COMBUSTIBLE NON-COMBUSTIBLE
BRICK
0” (0MM) IF
NON-COMBUSTIBLE
FINISHING IS USED
SUCH AS BRICK
AND STONE.
42 3/8"
1076mm
MINIMUM
PLUS RISE*
2" 51mm
MINIMUM
16"
406mm
1 1/2"
38mm
48 3/8"
1229mm
TOP EXIT ENCLOSURE
The appliance requires a minimum enclosure height
of 48 3/8" (1229mm). For temperature requirements,
the enclosure space around and above the appliance
must be left unobstructed.
REAR EXIT ENCLOSURE
The appliance requires a minimum enclosure height
of 39" (991mm). For temperature requirements, the
enclosure space around and above the appliance
must be left unobstructed.
* See "VENTING" section.
6.3.2 BGD36