Top of appliance, Warning, 4" 102mm – Napoleon Fireplaces Grandville 36 - BGD36 Manuel d'utilisation
Page 40: 8" 203mm, 2" 51mm, 6" 152mm

40
W415-0773 / F / 08.26.13
EN
TOP OF
APPLIANCE
WARNING: Non-combustible facing material may protrude from the top, and/or sides of this appliance,
as illustrated [up to a maximum of 6” (152.4mm)]. Greater than 6” (152.4mm) protrusions are considered a
mantel and must meet the combustible mantel requirements.
71.4B
4" (102mm)
2" (51mm)
6" (152mm)
FRONT OF
APPLIANCE
4" (102mm)
2" (51mm)
NON-COMBUSTIBLE
FACING MATERIAL
0" (0mm)
FINISH
MATERIAL
NON-COMBUSTIBLE
FACING MATERIAL
FINISH MATERIAL
2" (51mm)
4" (102mm)
6" (152mm)
4" (102mm)
2" (51mm)
0" (0mm)
6.6 NON-COMBUSTIBLE FACING MATERIAL
Combustible Mantel clearance can vary according to the Mantel depth. Use the graph
to help evaluate the clearance needed. These same requirements apply to any
combustibles protruding on either side of the appliance.
TOP OF APPLIANCE
6" 152mm
8"8" 203mm MANTEL
2" 51mm
4"
102mm
6"
152mm
8"
203mm
4" 102mm
2" 51mm
0
$
1
7
(
/
+
(
,
*
+
7
10” (254.0mm)
12” (304.8mm)
2
4
6
8 10 12
MANTEL DEPTH (INCHES)
8” (203.2mm)
4” (101.6mm)
6” (152.4mm)
2” (50.8mm)
!
WARNING
RISK OF FIRE, MAINTAIN ALL SPECIFIED AIR SPACE CLEARANCES TO COMBUSTIBLES. FAILURE
TO COMPLY WITH THESE INSTRUCTIONS MAY CAUSE A FIRE OR CAUSE THE APPLIANCE TO
OVERHEAT. ENSURE ALL CLEARANCES (I.E. BACK, SIDE, TOP, VENT, MANTEL, FRONT, ETC.) ARE
CLEARLY MAINTAINED.
WHEN USING PAINT OR LACQUER TO FINISH THE MANTEL, THE PAINT OR LACQUER MUST BE
HEAT RESISTANT TO PREVENT DISCOLOURATION.
73.1
6.5 MINIMUM MANTEL CLEARANCES