OPERATION

NOTE: Ensure the gas supply to the appliance is turned “ON”.

During the initial ignition cycle, air must be purged from the

gas line and thus it may take one to two minutes for the pilot

burner to ignite.

M,MS Models
Pilot Lighting Instructions

1. The in-line service shut-off valve should be in the “ON”

position.

2. With a lighted taper light the pilots which are located at

the rear of the main burner.

3. The pilot flame should be approximately 7/8”

(22 mm) long for proper ignition of the burners. The

pilot adjustment valve is located by sliding the drip

tray forward. The adjustment valves are located on the

manifold pipe, which runs horizontally across the back of

the unit, behind the drip tray, one is at the left rear and

the other is at the right rear.

4. To adjust the pilot light, turn the brass screw counter-

clockwise to increase the pilot flame, and clockwise to

decrease the flame.

NOTE: No more than 7/8” (22 mm) pilot flame length should

be required. Too high a setting will cause the flame to lift off

or will create excessive carboning. Do not adjust the pilot

flame lower than 7/8” (22mm) long because this can cause

delayed ignition at the burner. The delayed ignition could

cause the burner tiles to crack, in that case the burner would

have to be replaced.

Main Burner Operation

1. Turn the main burner to the “MAX” position.

2. Immediately check ignition of the burner.

CAUTION: Should ignition fail after five (5) seconds, turn the

valve off and wait five (5) minutes before trying again. The

pilot gas is not interrupted automatically, it is the responsibility

of the operator to check the ignition of the burners

immediately after the burner valve has been turned on.

Shut Down

1. Turn all valves to the “OFF” position by rotating the knob

clockwise 1/4 turn.

2. If the unit is to be shut down for an extended period of

time close the inline gas valve.

MST Models
Operating Controls

OFF

IGNITION

MAX

MIN

Lighting Instructions

1. Push in the tap and turn it counter-clockwise to the

Ignition Position “ ”

2. Holding the tap fully in, light the pilot with a match or

taper.