Chapter 3 : TECHNICAL SPECIFICATIONS
Power Supply:
+ 12Vdc (by the OCTO's DB9 connector).
Storage Temperature:
- 25 °C to + 85 °C (- 13 °F to + 185 °F).
Maximum ambient operating temperature: < 40 °C (< 104 °F).
Hygrometry:
10% to 80% (without condensation).
Dimensions:
D 115 x W 117 x H 55 mm / D 4.5" x W 4.6" x H 2.16".
Weight:
0.5 kg / 1.1 lbs.
Chapter 4 : WALL MOUNTING
To install the REMOTE KEYPAD in a standard 2-gang electrical box, proceed as follow :
c Remove the front panel of the REMOTE KEYPAD (4 screws).
d Disconnect the 5-pin MC connector (screw terminal) from the REMOTE KEYPAD'S PCB and disconnect the 4 wires
from the 5-pin MC connector.
e Connect the new cable on the 5-pin MC connector as shown below:
• Connect TX on PIN 3 of the OCTO
'
s DB9 connector.
• Connect RX on PIN 2 of the OCTO
'
s DB9 connector.
• Connect 0V on PIN 5 of the OCTO
'
s DB9 connector (only 1 wire is necessary).
• Connect 12V on PIN 8 of the OCTO
'
s DB9 connector.
PCB OF THE RK802-F
:
TX
RX
0V
12V
f Connect the 5-pin MC connector to the PCB of the REMOTE KEYPAD and install the front panel into the standard 2-
gang electrical box.
g Secure the front panel with the 4 screws.
Chapter 5 : WARRANTY
Analog Way warrants the product against any defects in material and workmanship for a period of three years from the date of
purchase (back to the factory).
In the event of any malfunction during the warranty period, Analog Way will, at its discretion, repair or replace the defective
unit, including free material and labor.
This warranty does not apply if the product has been :
- improperly installed or abused,
- handled with improper care,
- used or stocked in abnormal conditions,
- modified, opened,
- damaged by fire, war, or Natural disasters (Acts of God).
In no way shall Analog Way be responsible for direct or indirect loss of profit or consequential damages resulting from any
defect in this product.
In case of any problem, get the serial number of the unit, a description of the problem, and then call your authorized dealer.
OCTO
'
s DB9 F CONNECTOR:
AW
-RK802-Rev