Important Safety Information

READ AND FOLLOW ALL SAFETY INSTRUCTIONS

FOR YOUR SAFETY: Read these instructions carefully before operating the unit.

ELECTRICAL SPECIFICATIONS

1. All wiring must comply with local and national electrical codes and must be installed by a qualifi ed electrician. If you

have any questions regarding the following instructions, contact a qualifi ed electrician.

2. Check available power supply and resolve any wiring problems BEFORE installing and operating this unit.

3. This 115V or 230/208V air conditioner uses 11.7 or less nameplate amps and may be used in any properly wired,

general purpose household receptacle. See Table 1 for specifi cations for individual branch circuit.

4. For your safety and protection, this unit is grounded through the powercord plug when plugged into a matching wall

outlet. If you are not sure whether your wall outlet is properly grounded, please consult a qualifi ed electrician.

5. The wall outlet must match the 3-prong plug on the service cord supplied with the unit. DO NOT use plug adapters.

See Table 2 for receptacle and fuse information.

6. The rating plate on the unit contains electrical and other technical data. The rating plate is located on the right side of

the unit, above the powercord.

TABLE 1

Suggested Individual Branch Circuit

Nameplate Amps *AWG Wire Size
11.7 or less 14

AWG- American Wire Guage

*Based on copper wire at 105°C (221°F) temperature

rating.

TABLE 2

Recept and Fuse Types

Model

DAC150EC/UB1GDB DAC180EC/UB1GDB DAC250EC/UB1GDB

Rated Volts 125 240 250

Amps 15 15 30

Wall Outlet

Fuse Size 15 15 20

Time Delay Fuse Plug Type
(or Circuit Breaker)

Do not, under any
circumstances, cut,
remove, or bypass
the grounding prong.

2