CCI Thermal Technologies WMK - Wall Mounting Kit Manuel d'utilisation
Installer required to supply

Wall Mounting Kit Installation Instructions
For Heat Exchanger Unit Heaters
(En français à l’endos.)
WARNING:
If the heater is installed on a structure that is to be transported, provide additional support for
the heater during transit. The suspended weight should not exceed 300lbs (136kg). Refer to the
owner’s manual for mounting specifications and conditions.
Check that your heater model number corresponds to the model number shown on the mounting kit carton
.
Installer required to supply:
A method to fasten the two Z-Sections to the supporting structure. Four 3/8” diameter, grade 5
bolts are suggested, however, any method providing the same or greater strength may be used.
CONTENTS
Item Qty. Description
2 Z-Section
1 Arm Assembly
1 Mtg Attach Assy Bracket
4 Nut, 3/8 UNC
4 Bolt, 3/8 UNC x 1
4 Lock Washer, 3/8”
3 Bolt, 1/2 UNC x 1-1/4
3 Lock Washer, 1/2”
2 Nut, 1/2 UNC
1 Flat Washer, 1/2”
18” (457mm)
Recommended
mounting holes
12”
(307mm)
7-3/16”
(183mm)
�
���
�
�
21-13/16”
(554mm)
to wall
�
�
�
�
�
�
�
�
STEP 2
Bolt the Arm Assembly to
the Z-Sections using 3/8
UNC x 1 bolts, lock washers
and nuts
STEP 1
Fasten the Z-Sections to a wall
that will support the heater’s weight
using installer supplied fasteners.
STEP 3
Bolt Mtg Attach Assy Bracket
to the heater using 1/2 UNC x
1-1/4 bolts, lock washers, and
1/2 UNC nuts.
STEP 4
Lift the heater into place and fasten
it to the Arm Assembly using a
1/2 UNC x 1-1/4 bolt, lock washer
and flat washer. This step will
require more than one person due
to the weight of the heater. Refer to
the owner’s manual for the weight
of the heater.
Heater may
be rotated as
indicated by
arrows
Printed in Canada. Copyright 2007. All rights reserved.
Part No. 5757-1