e. Remove the terminal block from the socket and
connect the CNC cable to the terminal block
(TB) per the following chart (see NOTES after
chart):
TB
Connection
Description
1
Power Supply Output Voltage (ARC V +)
2
Power Supply Output Voltage (ARC V -)
3
High Side of START Signal (+15 vdc)
4
Low Side of START Signal (Common)
5
One Side of OK-To-Move Signal
6
Other Side of OK-To-Move Signal
ARC V.
START
OK TO
MOVE
+
1
2
3
4
5
6
-
+
-
A-02754
Figure 3-16 Terminal Block Positions
NOTES
ARC V+ Power supply positive output voltage
(work lead) connection to TB position 1 through a
100k resistor.
ARC V- Power supply negative output voltage
(torch electrode) connection to TB position 2
through a 100k resistor.
START + signal at TB position 3, 15 vdc at 10 ma,
must be brought low by connecting it to START -
at TB position 4, using a switch or relay contact,
to start the plasma torch.
OK-To-Move is a relay, rated at 115 VAC/28 vdc
at 2A, connected to TB positions 5 and 6 which
closes for the OK-To-Move signal when the cut-
ting arc is on.
Make sure all connections to the Terminal Block
(TB) are secure.
f. Reinstall the terminal block into the socket on
the Filter/Voltage Divider PC Board.
g. Secure the CNC cable by tightening the strain
relief.
h. Reinstall the Left Side Panel.
B. Optional Standoff Control SC11 Cable
The Standoff Control SC11 automatically finds height and
maintains torch standoff with a high speed torch lifter
motor. The unit consists of a remote operator's control,
torch lifter motor, and all cables required for installation.
It is ordered and shipped separately. Refer to the Stand-
off Control SC11 Instruction Manual for more informa-
tion.
The standoff control remote cable connects to the recep-
tacle J22 (CNC Control) on the rear panel of the Power
Supply.
J22
CNC Connector
A-02759
CNC or Remote Hand
Pendant Control Cable
Figure 3-17 Standoff Or Hand Pendant Control
Interface Connection
C. Optional Remote Hand Pendant Control
For automated systems, the optional Remote Hand Pen-
dant Control allows the operator to control system start
and stop functions from a remote location.
Connect the Remote Hand Pendant cable connector to
the receptacle J22 (CNC Control) on the rear panel of the
Power Supply.