Tweco 100XL Plus PAK Master Manuel d'utilisation
Page 29

Manual 0-2811
3-11
INSTALLATION
2. Using customer supplied CNC Cable
a. Remove the Left Side Panel from the Power
Supply as viewed from the front of the unit.
b. Remove the 7/8" knockout from the Rear
Panel and install a 1/2" NPT strain relief (not
supplied) into the hole.
CNC Knockout
A-02756
Rear Panel
1/2" (12.7 mm)
Strain Relief
(Customer Supplied)
Figure 3-13 Rear Panel Knockout Location
c. Locate the internal terminal block (TB) on the
Filter/Voltage Divider PC Board, located be-
hind the Logic PC Board. The terminal block
(TB) is plugged into a socket on the Filter/Volt-
age Divider PC Board.
A-02762
Logic PC Board
Internal Terminal
Block (TB)
Filter/Voltage Divider
PC Board
Figure 3-14 Internal Terminal Block Location
d. Feed the CNC cable through the strain relief
at the rear of the Power Supply, routing the
cable above the Logic PC Board to the Termi-
nal Block (TB).
A-02763
Internal Terminal
Block (TB)
CNC Cable Routing
Figure 3-15 Routing CNC Cable