Tweco 100XL Plus PAK Master Manuel d'utilisation
Page 16

INTRODUCTION
2-2
Manual 0-2811
5. Output Power
Continuously variable from 15 to 80 Amps maximum
6. Duty Cycle (Refer to NOTE)
Ambient
Temperature
Duty Cycle
40%
60%
100%
Current
80 Amps
n/a
60 Amps
DC Voltage
112 vdc
n/a
112 vdc
PakMaster 100XLP (Automated)
Duty Cycle
104° F
(40° C)
NOTE
The duty cycle will be reduced if the primary in-
put voltage (AC) is low or the DC voltage is higher
than shown in the chart.
7. Cut Capacity (Mild Steel)
Production:
3/8 inch (9.5 mm)
Genuine:
1 inch (25.4 mm)
Severance:
1-1/4 inch (31.8 mm)
8. Pilot Circuitry
Capacitive Discharge (CD), Pulsed DC
9. Weight
68 lbs ( 31 kg) w/work lead
75 lbs ( 34 kg) w/work lead, torch & lead
10. Overall Dimensions
19" (482 mm) High x 10.5" (267 mm) Wide x 24.8"
(630 mm) Long
Overall dimensions are with Handle, Gas Regulator/
Filter Assembly and Two Stage Air Filter installed.
B. Gas Regulator/Filter Assembly
Specifications
The following specifications apply to the Gas Regulator/
Filter Assembly only:
1. Gas regulator maximum gauge pressure
160 psi (11 bar)
2. Maximum input gas pressure
125 psi (8.6 bar)
3. Filter
Coalescent type filter
C. Two Stage Air Line Filter Specifications
The following specifications apply to the Two Stage Air
Line Filter Assembly only:
NOTE
The two stage air line filter is for use on systems
using compressed air.
1. Air Flow
15 scfm (425 lpm)
NOTE
Depending on the moisture in the air source the
weep drain on the bottom of the Filter should be
left open 1/4 turn at all times. The weep drain will
allow 10 scfh (10.7 lpm) of air to escape using 100
psi line pressure in the closed position. This will
allow water, oil and contamination to escape from
the filter.
2. Maximum input pressure
250 psi (17.2 bar)
3. Dew Point
10° to 35° F (-12° to 1.7° C) @ Atmospheric Pressure
4. Filtration
5 micron