Installation continued, Use and care – Garland HEEGM XX CL HIGH EFFICIENCY RADIANT CHAR-BROILER Manuel d'utilisation

Page 9

Advertising
background image

Part # 4530868 (04/25/12)

Page 9

INSTALLATION Continued

FOR HEEGM24 & 36 SIZE UNITS

• Connect a manometer to the test spigot on the

manifold.

• Turn on the unit and adjust the burners so that they are

all set to high.

• If necessary, adjust the pressure so that the reading

on the manometer matches the pressure value stated

on the rating plate. To adjust the pressure, access and

rotate the pressure adjustment screw on the regulator

installed at the appliance.

FOR HEEGM48 & 60 SIZE UNITS

• Connect a manometer to the test spigot on the LEFT

manifold.

• Turn on the LEFT side of the unit only (by activating the

left switch) and adjust the burners so that they are all

set to high.

• If necessary, adjust the pressure so that the reading

on the manometer matches the pressure value stated

on the rating plate. To adjust the pressure, access and

rotate the pressure adjustment screw on the regulator

installed at the appliance.

6. Inspect the flame of each burner to determine whether

adjustments to the burner air shutter are necessary.

Adjustments are made by loosening the air shutter screw;

rotating the shutter and re-tightening the screw. If the

tips of the flame appear too yellow, the shutter should be

turned to allow MORE air to enter the burner cavity. If the

flames appear to be lifting off the burner ports, the shutter

should be turned to allow LESS air to enter the burner

cavity.

Operation

IF FOR ANY REASON YOU SMELL GAS, BEFORE, DURING OR

AFTER OPERATION, TURN THE POWER OFF AND CLOSE THE

MANUAL SHUT-OFF VALVE TO THE APPLIANCE. CONTACT

AN AUTHORIZED SERVICE AGENT FOR SERVICE BEFORE

ATTEMPTING TO RESTORE GAS SUPPLY. FOR A LIST OF

AUTHORIZED SERVICE AGENTS, REFER TO THE GARLAND WEB

SITE AT http://www.garland-group.com

1. To turn on and use this appliance, the operator simply

needs to turn on the power switch(es).

FOR STANDARD 120 VOLT UNITS:

2. Models HEEGM-24CL and HEEGM-36CL have one power

switch on the lower right side of the unit. Once pushed

to the “ON” position, gas is supplied to all the burners. At

the same time a spark is supplied to each burner to ignite

the gas. Sparking will continue until a flame has been

established at all burners.

USE AND CARE

3. Models HEEGM-48CL and HEEGM-60CL have two power

switches on the lower right side of the unit. Once pushed

to the “ON” position, they operate in the same manner as

the single switch above, except they allow the operator to

run the left and right side of the broiler independently as

shown below:

• HEEGM-48CL: The left switch operates burners 1 to 4

on the left side of the unit. The right switch operates

burners 5 to 9 on the right side of the unit. The entire

unit runs when both switches are used.

• HEEGM-60CL: The left switch operates burners 1 to 6

on the left side of the unit. The right switch operates

burners 7 to 11 on the right side of the unit. The entire

unit runs when both switches are used.

FOR OPTIONAL 220-240 VOLT UNITS, THE MAIN

POWER SWITCH NEEDS TO BE TURNED ON BEFORE

THE FUNCTIONALITY OF THE SWITCHES DESCRIBED IN

2 & 3 APPLY. REFER TO IMAGES BELOW FOR A VISUAL

COMPARISON BETWEEN THE STANDARD 120 AND OPTIONAL

220-240V MODELS.

Advertising