Part # 4530868 (04/25/12)

Page 8

INSTALLATION Continued

and strain relief, and connected to the appropriate power

supply by a certified electrician in accordance with local

codes.

Gas Connection

ENSURE THE GAS METER AND GAS PIPING ARE SIZED

CORRECTLY FOR THE AMOUNT OF GAS FLOW AND PRESSURE

THAT WILL BE NEEDED TO RUN ALL APPLIANCES IN THE

KITCHEN. UNDERSIZED GAS PIPING INTO THE KITCHEN

MAY AFFECT THE PERFORMANCE OF THIS AND/OR OTHER

EQUIPMENT. IF IN DOUBT, CONSULT YOUR LOCAL GAS

AUTHORITY.

A MANUAL OR AUTOMATIC ISOLATION VALVE MUST BE

INSTALLED ON THE GAS SUPPLY TO THE KITCHEN FOR

ACCESS IN THE EVENT OF AN EMERGENCY. THE MANUAL

VALVE OR AUTOMATIC VALVE ACCESS POINT SHOULD BE

READILY ACCESSIBLE AND LOCATED EITHER OUTSIDE THE

KITCHEN OR CLOSE TO AN EXIT. POST THE FOLLOWING

NOTICE AT THE MANUAL VALVE OR AUTOMATIC VALVE

ACCESS POINT:

“ALL DOWNSTREAM BURNER AND PILOT VALVES MUST

BE TURNED OFF PRIOR TO RESTORING THE GAS SUPPLY.

AFTER AN EXTENDED SHUT OFF, PURGE BEFORE

RESTORING GAS.”

1. A manual gas shut-off valve must be installed in the gas

supply line ahead of the appliance for safety and ease

of future service. The shut-off valve should be located

such that it can be reached quickly in the event of an

emergency. The shut-off valve is normally supplied by the

installer.

2. This unit is shipped with a gas pressure regulator. It must

be installed at the appliance prior to connecting the

equipment to the gas line. Each appliance must have its

own pressure regulator. Be sure to install the regulator

according to the gas flow direction and verify that the

pressure marking corresponds with the gas type. Failure

to install a regulator will void the equipment warranty.

PRIOR TO CONNECTING THE REGULATOR, CHECK THE GAS

SUPPLY LINE PRESSURE. THE REGULATOR SUPPLIED WITH

THE UNIT IS RATED FOR A MAXIMUM OF ½ PSI (14” WC). IF

THE GAS SUPPLY LINE PRESSURE EXCEEDS THIS MAXIMUM,

A STEP DOWN REGULATOR WILL BE REQUIRED AND MUST BE

INSTALLED IN ACCORDANCE WITH LOCAL CODES.

THE RED AIR-VENT CAP IS PART OF THE REGULATOR AND

SHOULD NOT BE REMOVED, UNLESS LOCAL CODES REQUIRE

EXTERNAL VENTING. IF EXTERNAL VENTING IS REQUIRED,

INSTALL IN ACCORDANCE WITH LOCAL CODES.

3. A certified flexible gas hose and quick disconnect

assembly with suitable strain relief is recommended for

connection from the gas supply line to the unit. This will

allow the unit to be moved for future service.

FLEXIBLE HOSES & QUICK DISCONNECT DEVICES MUST

COMPLY WITH ALL LOCAL AUTHORITIES AND CODES.

IN NORTH AMERICA THIS INCLUDES ANSI Z21.69/CSA

6.16, ADDENDA Z21.69B-2006/CSA 6.16B-2006 (OR

LATEST EDITION) AND ANSI Z21.41/CSA 6.9, ADDENDA

Z21.41A-2005/CSA 6.16A-2005 (OR LATEST EDITION).

4. Only connect this unit to the type of gas shown on the

rating plate. Operating this unit with the wrong gas type

can result in abnormal performance, property damage,

injury or death.

5. Ensure that any new piping, joints and connections have

been made in a clean manner, so that dirt, threading

chips and/or other foreign matter will not clog pilots,

valves and/or controls. If necessary, purge new piping

prior to connecting the appliance. Use pipe sealant that

is certified for use with liquefied petroleum, for new joints

and/or connections, where sealant is required.

6. When pressure testing the gas supply piping to a

maximum of ½ psi (14” WC, 3.45 KPa), the appliance must

be isolated from the supply line by closing the manual

shut-off valve.

7. To ensure optimal operation of this unit, it is

recommended that the dynamic gas supply pressure into

the appliance regulator is a minimum of 1” WC higher than

the pressure stated on the rating plate.

Start Up

1. Inside the unit, ensure the burners are in the correct

position and the shields hanging under the burners have

not rotated out of position during transit.

2. Install cast radiants over each burner and place the

cooking grates in position on the unit.

3. Ensure the gas supply to the appliance is open and the

unit is connected to the power supply. Activating the one

or two power switches on the right leg operates the unit.

4. Check all gas connections for leaks using a soap solution.

Do not use an open flame to check for leaks. Be sure to

inspect connections outside and inside the unit (ie: valves,

manifold fittings and connections in the left leg channel)

to make certain all connections are gas tight after

shipping.

5. Verify the unit is running at the pressure stated on the

rating plate as follows: